Radiofrequency catheter ablation guided by intracardiac echocardiography.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Radiofrequency catheter ablation requires precise positioning of the ablation electrode. Fluoroscopically guided catheter manipulation has limitations, and there are risks of radiation exposure. The purpose of this study was to examine the feasibility of guiding catheter ablation within the right atrium with catheter-based intracardiac echocardiography. METHODS AND RESULTS: A 10F, 10-MHz intracardiac imaging catheter was used to direct an ablation electrode at four or five anatomic landmarks in the right atrium. Thirty-eight radiofrequency energy applications were performed in nine anesthetized dogs, and 38 lesions were identified on pathological examination. Lesions were created a mean of 1.9 +/- 2.1 mm from the ultrasound-guided site. Twenty-six of 38 lesions (68%) were less than 2.2 mm from the imaged site. Intracardiac echocardiography also was used to confirm stable electrode-endocardial contact in 37 energy applications (97%) and identified catheter movement in 9 energy applications (24%). Discrete lesions, microcavitations, and thrombi were observed in 13 (34%), 23 (61%), and 19 (50%) of 38 energy applications, respectively. Microcavitations predicted the appearance of thrombus. Fluoroscopy time required to create four or five lesions decreased from 23 minutes in the first study to less than 2 minutes in the last five studies. CONCLUSIONS: Catheter-based intracardiac echocardiography can accurately guide catheter ablation directed at anatomic landmarks and potentially reduced ionizing radiation exposure. Intracardiac imaging can be used to confirm endocardial contact, identify electrode movement, and directly visualize lesions. Intracardiac echocardiography also can be used to identify microcavitations, which predict thrombus formation during radiofrequency energy applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Cited by
Olgin, J. E., Kalman, J. M., Fitzpatrick, A. P., & Lesh, M. D. (1995) · Circulation · doi:10.1161/01.cir.92.7.1839 · Cited by 500
Self-citationKalman, J. M., Olgin, J. E., Karch, M. R., Hamdan, M., Lee, R. J., & Lesh, M. D. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00492-0 · Cited by 343
Self-citationRadiofrequency catheter modification of the sinus node for “inappropriate” sinus tachycardia
Lee, R. J., Kalman, J. M., Fitzpatrick, A. P., Epstein, L. M., Fisher, W. G., Olgin, J. E., Lesh, M. D., & Scheinman, M. M. (1995) · Circulation · doi:10.1161/01.cir.92.10.2919 · Cited by 213
Self-citationSchumacher, B., Jung, W., Schmidt, H., Fischenbeck, C., Lewalter, T., Hagendorff, A., Omran, H., Wolpert, C., & Lüderitz, B. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00211-9 · Cited by 104
Metadata
- Authors
- Chu, E., Fitzpatrick, A. P., Chin, M. C., Sudhir, K., Yock, P. G., & Lesh, M. D.
- Venue
- Circulation
- Published
- 1994-03
- Volume
- 89
- Issue
- 3
- Pages
- 1301-1305
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2060490776
- Cited by
- 142
- References
- 1
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiofrequency catheter ablation guided by intracardiac echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.89.3.1301
- The paper
- Chu, E., Fitzpatrick, A. P., Chin, M. C., Sudhir, K., Yock, P. G., & Lesh, M. D. (1994). Radiofrequency catheter ablation guided by intracardiac echocardiography. Circulation. https://doi.org/10.1161/01.cir.89.3.1301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.