The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Microvascular integrity indicates myocellular viability in patients with recent myocardial infarction. New insights using myocardial contrast echocardiography.
Open accessAbstract
BACKGROUND: Patency of the infarct-related artery (IRA) after acute myocardial infarction (AMI) may not reflect the magnitude of tissue perfusion. In animal models of AMI, myocardial cellular necrosis has been associated with extensive capillary damage. Because myocardial contrast echocardiography (MCE) can define the spatial distribution of microvascular perfusion, we hypothesized that it could be used in patients after recent AMI to distinguish myocardial regions that have an intact microvasculature and thus are viable from those without an intact microvasculature and thus are not viable. METHODS AND RESULTS: One hundred five patients with a recent AMI (range, 1 day to 4 weeks; median, 8 days) who were undergoing cardiac catheterization were included in the study. Two-dimensional echocardiography was performed at baseline and repeated 1 month later to assess regional function within the infarct zone (scores of 1 to 5 indicating normal to dyskinetic segments, respectively). MCE was performed in the cardiac catheterization laboratory to assess microvascular perfusion within the infarct bed. A contrast score index was derived by assigning scores to individual segments within the infarct zone (0, 0.5, and 1 denoting no, intermediate, and homogeneous contrast effect, respectively) and deriving the average score within the infarct bed. Revascularization was performed as clinically indicated. Although the baseline wall motion score and the contrast score index were similar in the 90 patients with a patent IRA and the 15 patients with an occluded IRA (median +/- 1 interquartile range, 3 +/- 1 versus 3.5 +/- 1; P = .41), wall motion score 1 month later was significantly better in those with open IRAs compared with those with closed IRAs (2 +/- 2 versus 3 +/- 2, P = .05). In the 90 patients with an open IRA, a strong correlation was noted between wall motion score 1 month later and the contrast score index (rho = -.64, P < .001). On multivariate analysis, the best correlate of the 1-month wall motion score was the contrast score index. CONCLUSIONS: In patients studied in the cardiac catheterization laboratory between 1 day and 4 weeks after AMI, an intact microvasculature as identified by MCE indicates myocardial regions that improve function 1 month later. This study demonstrates that microvascular patency is closely associated with myocardial cellular viability after AMI in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The “no-reflow” phenomenon after temporary coronary occlusion in the dog
Kloner, R. A., Ganote, C. E., & Jennings, R. B. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107898 · Cited by 1,842
Cited by
Stunning, Hibernation, and Assessment of Myocardial Viability
Camici, P. G., Prasad, S. K., & Rimoldi, O. E. (2008) · Circulation · doi:10.1161/circulationaha.107.702993 · Cited by 409
Iwakura, K., Ito, H., Ikushima, M., Kawano, S., Okamura, A., Asano, K., Kuroda, T., Tanaka, K., Masuyama, T., Hori, M., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02626-8 · Cited by 408
Metadata
- Authors
- Ragosta, M., Camarano, G., Kaul, S., Powers, E. R., Sarembock, I. J., & Gimple, L. W.
- Venue
- Circulation
- Published
- 1994-06
- Volume
- 89
- Issue
- 6
- Pages
- 2562-2569
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2064778528
- Cited by
- 368
- References
- 1
- FWCI
- 21.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microvascular integrity indicates myocellular viability in patients with recent myocardial infarction. New insights using myocardial contrast echocardiography. https://app.cochat.ai/papers/10.1161/01.cir.89.6.2562
- The paper
- Ragosta, M., Camarano, G., Kaul, S., Powers, E. R., Sarembock, I. J., & Gimple, L. W. (1994). Microvascular integrity indicates myocellular viability in patients with recent myocardial infarction. New insights using myocardial contrast echocardiography. Circulation. https://doi.org/10.1161/01.cir.89.6.2562
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.