The DOI matches its Crossref record.
Optical mapping of repolarization and refractoriness from intact hearts.
Abstract
BACKGROUND: Heterogeneities of repolarization (R) across the myocardium have been invoked to explain most reentrant arrhythmias. The measurement of refractory periods (RPs) has been widely used to assess R, but conventional electrode and extrastimulus mapping techniques have not provided reliable maps of RPs. METHODS AND RESULTS: Guinea pig hearts were stained with a voltage-sensitive dye to measure fluorescence (F) action potentials (APs) from 124 sites with a photodiode array. AP duration (APD) was defined as the time between depolarization (dF/dt)max and R time points (ie, the time when AP returns to baseline or some percent thereof). However, R time points are difficult to determine because AP downstrokes are often encumbered by drifting baselines and motion artifacts, which make this definition ambiguous. In optical and microelectrode recordings, the second derivative of AP downstrokes is shown to contain an easily detected, unique local maximum. The correlation between the position of this maximum (d2F/dt2)max and R has been tested during altered AP characteristics induced by changes in cycle length, ischemia, and hypoxia. Under these various modifications of the AP, the time points of (d2F/dt2)max fell at 97.0 +/- 2.1% of recovery to baseline. Extrastimulus techniques applied to (1) isolated myocytes, (2) intact hearts, and (3) mathematical simulations indicated that (d2V/dt2)max coincided with the effective RPs of APs. The coincidence of RPs and (d2V/dt2)max was valid within 5 milliseconds, for resting potentials of -75 to -90 mV and extrastimuli three times threshold voltage. CONCLUSIONS: Thus, optical APs and (d2F/dt2)max can be used to map activation, R, and RPs with AP recordings from a single heartbeat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
El-Sherif, N., Caref, E. B., Yin, H., & Restivo, M. (1996) · Circulation Research · doi:10.1161/01.res.79.3.474 · Cited by 425
Efimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390
Self-citationArrhythmogenic Substrate of the Pulmonary Veins Assessed by High-Resolution Optical Mapping
Arora, R., Verheule, S., Scott, L., Navarrete, A., Katari, V., Wilson, E., Vaz, D., & Olgin, J. E. (2003) · Circulation · doi:10.1161/01.cir.0000058461.86339.7e · Cited by 345
Transmural Dispersion of Repolarization in Failing and Nonfailing Human Ventricle
Glukhov, A. V., Fedorov, V. V., Lou, Q., Ravikumar, V. K., Kalish, P. W., Schuessler, R. B., Moazami, N., & Efimov, I. R. (2010) · Circulation Research · doi:10.1161/circresaha.109.204891 · Cited by 315
Self-citationBrain micromotion around implants in the rodent somatosensory cortex
Gilletti, A., & Muthuswamy, J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/001 · Cited by 307
Metadata
- Authors
- Efimov, I. R., Huang, D. T., Rendt, J. M., & Salama, G.
- Venue
- Circulation
- Published
- 1994-09
- Volume
- 90
- Issue
- 3
- Pages
- 1469-1480
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2019941324
- Cited by
- 195
- References
- 0
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical mapping of repolarization and refractoriness from intact hearts. https://app.cochat.ai/papers/10.1161/01.cir.90.3.1469
- The paper
- Efimov, I. R., Huang, D. T., Rendt, J. M., & Salama, G. (1994). Optical mapping of repolarization and refractoriness from intact hearts. Circulation. https://doi.org/10.1161/01.cir.90.3.1469
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.