Characteristics of the ventricular insertion sites of accessory pathways with anterograde decremental conduction properties
Abstract
BACKGROUND: Accessory pathways (APs) with anterograde decremental conduction properties referred to as Mahaim fibers have recently been recognized as originating from the right lateral atrium. Little information is available about their distal insertion. The purpose of this study was to determine the different kinds of APs involved and the characteristics of their distal insertion site. METHODS AND RESULTS: Twenty-one patients (mean age, 28 +/- 13 years) with reciprocating tachycardia or atrial fibrillation were studied. Right-sided atrial and/or ventricular endocardial mapping during tachycardia identified different types of APs. (1) Seventeen patients had long APs originating from the right lateral atrium and coursing several centimeters to the right ventricle. In 10 patients, the AP terminated in or close to the right bundle-branch system (atriofascicular AP) and in 7, the AP terminated in the anterior right ventricle (atrioventricular AP). Patients with atriofascicular APs had narrower QRS complexes (133 +/- 10 versus 165 +/- 26 milliseconds, P = .02) and narrower initial r wave in leads V2 through V4 during maximal preexcitation than patients with atrioventricular APs. In addition, they had earlier His-bundle and right bundle-branch retrograde activation, ie, shorter V-His (16 +/- 5 versus 37 +/- 9 milliseconds, P < .01) and V-right bundle intervals (3 +/- 5 versus 25 +/- 6 milliseconds, P < .01). In 6 patients, minimal preexcitation not readily apparent was present in sinus rhythm despite the appearance of a narrow QRS complex. A wide distal insertion site of 0.5 to 2 cm in diameter consistent with arborization of the AP was found in 10 patients. The distal application of radiofrequency current produced a change in the preexcitation pattern in 4 patients and ablated the AP in 2 patients. In the other patients, radiofrequency current was applied more proximally and successfully ablated the AP bundle (n = 9) or AP proximal insertion (n = 6). No recurrence was observed during a follow-up period of 12 +/- 10 months. (2) Four patients had short paratricuspid atrioventricular APs; in one, the decremental conduction property was acquired as demonstrated by two electrophysiological studies performed 7 years apart. Radiofrequency ablation was successfully accomplished in all 4 patients at the tricuspid annulus. CONCLUSIONS: Different types of APs account for tachycardias previously called Mahaim fibers. Long and short atrioventricular APs are observed in 81% and 19%, respectively. Long APs often have a distal arborization and may have either a fascicular or ventricular insertion. Radiofrequency current is more efficient when applied to the AP bundle or AP proximal insertion rather than to the distal insertion in patients with long APs.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Mahaim fibers are nodoventricular or atriofascicular decrementally conducting connections between the right atrium or AV node and the right ventricle in or close to the right bundle branch.
“Mahaim fibers are nodoventricular (as initially described) or atriofascicular (more often) decrementally conducting connections between the right atrium or the AV node and the right ventricle in or close to the right bundle branch.329 -332”
From European Heart Rhythm Association (EHRA) consensus document on the management of supraventricular arrhythmias, endorsed by Heart Rhythm Society (HRS), Asia-Pacific Heart Rhythm Society (APHRS), and Sociedad Latinoamericana de Estimulacion Cardiaca y Electrofisiologia (SOLAECE) (2017) · cites this paper as [331]
The citation lists haven’t been fetched yet
References 36 · Cited by 146
- Authors
- Haı̈ssaguerre, M., Cauchemez, B., Marcus, F., Le Métayer, P., Lauribe, P., Poquet, F., Gencel, L., & Clémenty, J.
- Affiliations
- University of Arizona (US)
- From the Hôpital Cardiologique du Haut-Lévêque, Avenue de Magellan, 33604 Pessac Cédex, France, and Department of Medicine, University of Arizona College of Medicine (F.M.), Tucson, Ariz.
- Venue
- Circulation
- Published
- 1995-02-15
- Volume
- 91
- Issue
- 4
- Pages
- 1077-1085
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2089551494
- Cited by
- 146
- References
- 36
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 4 · 2022: 13 · 2021: 3 · 2020: 5 · 2019: 7 · 2018: 6 · 2017: 6 · 2016: 4 · 2015: 6 · 2014: 3 · 2013: 2 · 2012: 5
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- accessory pathway, Mahaim fibers, reciprocating tachycardia, atrial fibrillation, radiofrequency catheter ablation, preexcitation, endocardial mapping
- MeSH terms
- Adult, Atrial Fibrillation, Bundle-Branch Block, Cardiac Pacing, Artificial, Electrocardiography, Female, Heart Conduction System, Humans, Male, Pre-Excitation, Mahaim-Type, Tachycardia, Paroxysmal, Catheter Ablation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review