The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Mechanoelectrical Interaction in Tetralogy of Fallot: QRS Prolongation Relates to Right Ventricular Size and Predicts Malignant Ventricular Arrhythmias and Sudden Death
Abstract
Background Life-threatening ventricular arrhythmia and sudden death remain serious late complications after tetralogy of Fallot repair. Nevertheless, there remains no clear way of predicting which patients are at risk. Methods and Results The study population included a total of 178 adult survivors (mean follow-up, 21.4 years) of tetralogy of Fallot repair who were currently attending our clinic. Mechanoelectrical relations were sought in 41 of the patients (mean follow-up, 23.6 years) who were operated on by one surgeon and who were prospectively studied with a 12-lead ECG, chest radiography, and two-dimensional and Doppler echocardiography. Nine patients (mean follow-up, 17 years) from the total group of 178 were identified as having had sustained ventricular tachycardia (8 with near-miss sudden death), and their ECGs, Holter monitor readings, electrophysiological studies, and chest radiographs were reviewed. The case notes of an additional 4 patients with postoperative sudden cardiac death also were available for review. QRS duration in the 41 patients in whom mechanoelectrical interaction was sought ranged between 90 and 200 milliseconds and correlated with cardiothoracic ratio (CTR) on chest radiography ( r =.64, P <.001) and with right ventricular size on echocardiography ( r =.43, P <.02). Twenty of the 41 patients had restrictive right ventricular Doppler physiology (reduced ventricular compliance) with mean QRS duration of 129.3±20 milliseconds and mean CTR of 0.51±0.03. The remaining 21 patients with no evidence of right ventricular restriction had prolonged QRS duration of 157.5±13.2 milliseconds ( P <.001) and CTR of 0.55±0.04 ( P <.04) compared with the restrictive. In the 9 patients with ventricular tachycardia, the QRS duration ranged from 180 to 230 milliseconds (mean, 198.9±17.6 milliseconds), and the CTR ranged from 0.54 to 0.9 (mean, 0.67±0.12) ( P <.0001 and P <.01, respectively, compared with patients without life-threatening arrhythmias). All patients with documented sustained ventricular tachycardia and the 4 patients with sudden death had a QRS duration of ≥180 milliseconds (100% sensitivity). Conclusions Chronic right ventricular volume overload after tetralogy of Fallot repair is related to diastolic function and correlates with QRS prolongation. The risk of symptomatic arrhythmia is high when marked right ventricular enlargement and QRS prolongation develop. A QRS duration on the resting ECG of ≥180 milliseconds is the most sensitive predictor of life-threatening ventricular arrhythmias yet described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Cardiac Arrhythmia Suppression Trial (CAST) Investigators (1989) · New England Journal of Medicine · doi:10.1056/nejm198908103210629 · Cited by 3,300
Long-term outcome in patients undergoing surgical repair of tetralogy of Fallot
Murphy, J. G., Gersh, B. J., Mair, D. D., Fuster, V., McGoon, M. D., Ilstrup, D. M., McGoon, D. C., Kirklin, J. W., & Danielson, G. K. (1993) · New England Journal of Medicine · doi:10.1056/nejm199308263290901 · Cited by 998
LILLEIIEI, C. W., COHEN, M., WARDEN, H. E., READ, R. C., AUST, J. B., DEWALL, R. A., & VARCO, R. L. (1955) · Annals of Surgery · doi:10.1097/00000658-195509000-00010 · Cited by 485
Gatzoulis, M. A., Clark, A. L., Cullen, S., Newman, C. G. H., & Redington, A. N. (1995) · Circulation · doi:10.1161/01.cir.91.6.1775 · Cited by 410
Self-citationLife expectancy without surgery in tetralogy of fallot
Bertranou, E. G., Blackstone, E. H., Hazelrig, J. B., Turner, M. E., & Kirklin, J. W. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90941-4 · Cited by 347
Wellens, H. J., Brugada, P., & Stevenson, W. G. (1985) · Circulation · doi:10.1161/01.cir.72.1.1 · Cited by 306
Hansen, D. E., Craig, C. S., & Hondeghem, L. M. (1990) · Circulation · doi:10.1161/01.cir.81.3.1094 · Cited by 274
Carvalho, J. S., Shinebourne, E. A., Busst, C., Rigby, M. L., & Redington, A. N. (1992) · Heart · doi:10.1136/hrt.67.6.470 · Cited by 262
Self-citationStatus of the adult and adolescent after repair of tetralogy of Fallot.
Garson, A., Nihill, M. R., McNamara, D. G., & Cooley, D. A. (1979) · Circulation · doi:10.1161/01.cir.59.6.1232 · Cited by 243
Exercise performance in tetralogy of Fallot after intracardiac repair
Wessel, H. U., Cunningham, W. J., Paul, M. H., Bastanier, C. K., Muster, A. J., & Idriss, F. S. (1980) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)37745-1 · Cited by 216
Cited by
Zipes, D. P., & Wellens, H. J. J. (1998) · Circulation · doi:10.1161/01.cir.98.21.2334 · Cited by 2,744
ESC Guidelines for the management of grown-up congenital heart disease (new version 2010)
Endorsed by the Association for European Paediatric Cardiology (AEPC), Authors/Task Force Members, Baumgartner, H., Bonhoeffer, P., De Groot, N. M. S., de Haan, F., Deanfield, J. E., Galie, N., Gatzoulis, M. A., Gohlke-Baerwolf, C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq249 · Cited by 2,331
Self-citationWarnes, C. A., Williams, R. G., Bashore, T. M., Child, J. S., Connolly, H. M., Dearani, J. A., del Nido, P., Fasules, J. W., Graham, T. P., Hijazi, Z. M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190811 · Cited by 2,066
Gatzoulis, M. A., Balaji, S., Webber, S. A., Siu, S. C., Hokanson, J. S., Poile, C., Rosenthal, M., Nakazawa, M., Moller, J. H., Gillette, P. C., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02714-8 · Cited by 1,779
Self-citationACC/AHA 2008 Guidelines for the Management of Adults With Congenital Heart Disease
Warnes, C. A., Williams, R. G., Bashore, T. M., Child, J. S., Connolly, H. M., Dearani, J. A., del Nido, P., Fasules, J. W., Graham, T. P., Hijazi, Z. M., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.10.001 · Cited by 1,533
Metadata
- Authors
- Gatzoulis, M. A., Till, J. A., Somerville, J., & Redington, A. N.
- Venue
- Circulation
- Published
- 1995-07-15
- Volume
- 92
- Issue
- 2
- Pages
- 231-237
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2087890169
- Cited by
- 786
- References
- 31
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanoelectrical Interaction in Tetralogy of Fallot: QRS Prolongation Relates to Right Ventricular Size and Predicts Malignant Ventricular Arrhythmias and Sudden Death. https://app.cochat.ai/papers/10.1161/01.cir.92.2.231
- The paper
- Gatzoulis, M. A., Till, J. A., Somerville, J., & Redington, A. N. (1995). Mechanoelectrical Interaction in Tetralogy of Fallot: QRS Prolongation Relates to Right Ventricular Size and Predicts Malignant Ventricular Arrhythmias and Sudden Death. Circulation. https://doi.org/10.1161/01.cir.92.2.231
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.