Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 463

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Physiological Basis of Myocardial Contrast Enhancement in Fast Magnetic Resonance Images of 2-Day-Old Reperfused Canine Infarcts

Judd, Robert M., Lugo-Olivieri, Carlos H., Arai, Masazumi, Kondo, Takeshi, Croisille, Pierre, Lima, Joao A.C., Mohan, Vivek, Becker, Lewis C., Zerhouni, Elias A.·1995·Circulation

Abstract

Background Contrast-enhanced fast magnetic resonance (MR) images of acute, reperfused human infarcts demonstrate regions of hypoenhancement and hyperenhancement. The relations between the spatial extent and time course of these enhancement patterns to myocardial risk, infarct, and no-reflow regions have not been well characterized. Methods and Results The proximal left anterior descending coronary artery was occluded in 11 closed-chest dogs for 90 minutes followed by 2 days of reperfusion. Regional blood flow was determined by use of radioactive microspheres. The animals were studied at the 2-day time point with contrast-enhanced fast MRI (Signa 1.5 T, General Electric). Thioflavin-S was administered to demarcate no-reflow regions. The hearts were then excised, sectioned into five base-to-apex slices, stained with 2,3,5-triphenyltetrazolium chloride (TTC), and photographed under room light (for TTC) and ultraviolet light (for thioflavin). The spatial extents of thioflavin-negative, TTC-negative, and risk regions were compared planimetrically with MRI hypoenhanced and hyperenhanced regions. The spatial locations of subendocardial hypoenhancement in MR images correlated closely with those of thioflavin-negative regions. Microsphere blood flow in these regions was significantly reduced compared with remote regions (0.37±0.09 versus 0.88±0.10 mL/min per gram, respectively, P <.001) and with baseline (0.37±0.09 versus 0.87±0.15 mL/min per gram, P <.01). The spatial extent of hyperenhancement was smaller than the risk region ( r =.64, slope=0.48, P <.001) but highly correlated with TTC-negative regions and were, on average, 12% larger ( r =.93, slope=1.12, P =.035). Conclusions In contrast-enhanced MR images of 2-day-old reperfused canine infarcts, myocardial regions of hypoenhancement are related to the no-reflow phenomenon. Approximately 90% of the myocardium within hyperenhanced regions is nonviable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.92.7.1902

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 463

Metadata

Authors
Judd, R. M., Lugo-Olivieri, C. H., Arai, M., Kondo, T., Croisille, P., Lima, J. A. C., Mohan, V., Becker, L. C., & Zerhouni, E. A.
Venue
Circulation
Published
1995-10
Volume
92
Issue
7
Pages
1902-1910
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2066789731
Cited by
463
References
1
FWCI
7.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physiological Basis of Myocardial Contrast Enhancement in Fast Magnetic Resonance Images of 2-Day-Old Reperfused Canine Infarcts. https://app.cochat.ai/papers/10.1161/01.cir.92.7.1902
The paper
Judd, R. M., Lugo-Olivieri, C. H., Arai, M., Kondo, T., Croisille, P., Lima, J. A. C., Mohan, V., Becker, L. C., & Zerhouni, E. A. (1995). Physiological Basis of Myocardial Contrast Enhancement in Fast Magnetic Resonance Images of 2-Day-Old Reperfused Canine Infarcts. Circulation. https://doi.org/10.1161/01.cir.92.7.1902

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.