The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Simultaneous Transmission/Emission Myocardial Perfusion Tomography: Diagnostic Accuracy of Attenuation-Corrected 99m Tc-Sestamibi Single-Photon Emission Computed Tomography
Abstract
Background The purpose of the present study was to assess the diagnostic performance of attenuation-corrected (AC) stress 99m Tc-sestamibi cardiac single-photon emission computed tomography (SPECT) for the identification of coronary heart disease (CHD). Methods and Results With a triple-detector SPECT system with a 241 Am transmission line source, simultaneous transmission/emission tomography (TCT/ECT) was performed on 60 patients with angiographic coronary disease and 59 patients with ≤5% likelihood of CHD. Iteratively reconstructed AC stress 99m Tc-sestamibi perfusion images were compared with uncorrected (NC) filtered-backprojection images. Normal database polar maps were constructed from AC and NC images for quantitative analyses. From the low-likelihood patients, the visual and quantitative normalcy rates increased from 0.88 and 0.76 for NC to 0.98 and 0.95 for AC ( P <.05). For the detection of CHD, the receiver operating characteristic curves for the AC images demonstrated improved discrimination capacity ( P <.05), and sensitivity/specificity values increased from 0.78/0.46 (NC) to 0.84/0.82 (AC) with visual analysis and from 0.84/0.46 (NC) to 0.88/0.82 (AC) with quantitative analysis. For localization of stenosed vessels, visual and quantitative sensitivity values were 0.51 and 0.63 for NC and 0.64 and 0.78 for AC images ( P <.05), respectively. Conclusions TCT/ECT myocardial perfusion imaging significantly improves the diagnostic accuracy of cardiac SPECT for the detection and localization of CHD. Clinical use of TCT/ECT imaging deserves serious consideration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Note on the Sampling Error of the Difference Between Correlated Proportions or Percentages
McNemar, Q. (1947) · Psychometrika · doi:10.1007/bf02295996 · Cited by 4,754
Analysis of probability as an aid in the clinical diagnosis of coronary artery disease.
Diamond, G. A., & Forrester, J. S. (1979) · New England Journal of Medicine · doi:10.1056/nejm197906143002402 · Cited by 2,664
A Method for Attenuation Correction in Radionuclide Computed Tomography
Chang, L.-T. (1978) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1978.4329385 · Cited by 1,297
White, C. W., Wright, C. B., Doty, D. B., Hiratza, L. F., Eastham, C. L., Harrison, D. G., & Marcus, M. L. (1984) · New England Journal of Medicine · doi:10.1056/nejm198403293101304 · Cited by 1,222
Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size
Hoffman, E. J., Huang, S.-C., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,143
Interobserver variability in coronary angiography.
Zir, L. M., Miller, S. W., Dinsmore, R. E., Gilbert, J. P., & Harthorne, J. W. (1976) · Circulation · doi:10.1161/01.cir.53.4.627 · Cited by 768
Penalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
Self-citationA local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
Quantification of rotational thallium-201 myocardial tomography.
Garcia, E. V., Train, K. F. V., Maddahi, J., Prigent, F., Friedman, J. D., Areeda, J. S., Waxman, A. D., & Berman, D. S. (1985) · PubMed · Cited by 419
Cited by
Ollinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
Self-citationGibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00150-3 · Cited by 633
Single photon-emission computed tomography
Holly, T. A., Abbott, B. G., Al-Mallah, M., Calnon, D. A., Cohen, M. C., DiFilippo, F. P., Ficaro, E. P., Freeman, M. R., Hendel, R. C., Jain, D., et al. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9246-y · Cited by 597
Self-citationEANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
Hesse, B., Tägil, K., Cuocolo, A., Anagnostopoulos, C., Bardiés, M., Bax, J., Bengel, F., Busemann Sokole, E., Davies, G., Dondi, M., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1779-y · Cited by 527
Underwood, S. R., Anagnostopoulos, C., Cerqueira, M., Ell, P. J., Flint, E. J., Harbinson, M., Kelion, A. D., Al-Mohammad, A., Prvulovich, E. M., Shaw, L. J., et al. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1344-5 · Cited by 481
Metadata
- Authors
- Ficaro, E. P., Fessler, J. A., Shreve, P. D., Kritzman, J. N., Rose, P. A., & Corbett, J. R.
- Venue
- Circulation
- Published
- 1996-02
- Volume
- 93
- Issue
- 3
- Pages
- 463-473
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2044819115
- Cited by
- 313
- References
- 15
- FWCI
- 22.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Transmission/Emission Myocardial Perfusion Tomography: Diagnostic Accuracy of Attenuation-Corrected 99m Tc-Sestamibi Single-Photon Emission Computed Tomography. https://app.cochat.ai/papers/10.1161/01.cir.93.3.463
- The paper
- Ficaro, E. P., Fessler, J. A., Shreve, P. D., Kritzman, J. N., Rose, P. A., & Corbett, J. R. (1996). Simultaneous Transmission/Emission Myocardial Perfusion Tomography: Diagnostic Accuracy of Attenuation-Corrected 99m Tc-Sestamibi Single-Photon Emission Computed Tomography. Circulation. https://doi.org/10.1161/01.cir.93.3.463
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.