The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Abstract
Background Optical coherence tomography (OCT) is a recently developed medical diagnostic technology that uses back-reflected infrared light to perform in situ micron scale tomographic imaging. In this work, we investigate the ability of OCT to perform micron scale tomographic imaging of the internal microstructure of in vitro atherosclerotic plaques. Methods and Results Aorta and relevant nonvascular tissue were obtained at autopsy. Two-dimensional cross-sectional imaging of the exposed surface of the arterial segments was performed in vitro with OCT. A 1300-nm wavelength, superluminescent diode light source was used that allows an axial spatial resolution of 20 μm. The signal-to-noise ratio was 109 dB. Images were displayed in gray scale or false color. Imaging was performed over 1.5 mm into heavily calcified tissue, and a high contrast was noted between lipid- and water-based constituents, making OCT attractive for intracoronary imaging. The 20-μm axial resolution of OCT allowed small structural details such as the width of intimal caps and the presence of fissures to be determined. The extent of lipid collections, which had a low backscattering intensity, also were well documented. Conclusions OCT represents a promising new technology for imaging vascular microstructure with a level of resolution not previously achieved with the use of other imaging modalities. It does not require direct contact with the vessel wall and can be performed with a catheter integrated with a relatively inexpensive optical fiber. The high contrast among tissue constituents, high resolution, and ability to penetrate heavily calcified tissue make OCT an attractive new imaging technology for intracoronary diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cited by
Measurement of the thickness of the fibrous cap by optical coherence tomography
Kume, T., Akasaka, T., Kawamoto, T., Okura, H., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.06.030 · Cited by 273
Metadata
- Authors
- Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G.
- Venue
- Circulation
- Published
- 1996-03-15
- Volume
- 93
- Issue
- 6
- Pages
- 1206-1213
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2134085852
- Cited by
- 566
- References
- 1
- FWCI
- 21.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology. https://app.cochat.ai/papers/10.1161/01.cir.93.6.1206
- The paper
- Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996). Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology. Circulation. https://doi.org/10.1161/01.cir.93.6.1206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.