Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Assessment of Coronary Arterial Flow and Flow Reserve in Humans With Magnetic Resonance Imaging

Hundley, W. Gregory, Lange, Richard A., Clarke, Geoffrey D., Meshack, Benjamin M., Payne, Jerry, Landau, Charles, McColl, Roderick, Sayad, Dany E., Willett, DuWayne L., Willard, John E., Hillis, L. David, Peshock, Ronald M. · 1996 · Circulation

Abstract

Background The noninvasive measurement of absolute epicardial coronary arterial flow and flow reserve would be useful in the evaluation of patients with coronary circulatory disorders. Phase-contrast magnetic resonance imaging (PC-MRI) has been used to measure coronary arterial flow in animals, but its accuracy in humans is unknown. Methods and Results Twelve subjects (7 men, 5 women; age, 44 to 67 years) underwent PC-MRI measurements of flow in the left anterior descending coronary artery or one of its diagonal branches at rest and after administration of adenosine (140 μg·kg−1·min−1 IV). Immediately thereafter, intracoronary Doppler velocity (IDV) and flow measurements were made during cardiac catheterization at rest and after intravenous administration of adenosine. For the 12 patients, the correlation between MRI and invasive measurements of coronary arterial flow and coronary arterial flow reserve was excellent: coronary flow MRI(mL/min)= 0.85×coronary flow IDV(mL/min)+17 (mL/min),r=.89, and coronary flow reserve MRI=0.79×coronary velocity reserve IDV+0.34,r=.89. For the range of coronary arterial flows (18 to 161 mL/min) measured by MRI, the limit of agreement between MRI and catheterization measurements of flow was −13±30 mL/min; for the range of coronary reserves (0.7 to 3.7) measured by MRI, the limit of agreement between the two techniques was 0.1±0.4. Conclusions Cine velocity-encoded PC-MRI can noninvasively measure absolute coronary arterial flow in the left anterior descending artery in humans. PC-MRI can detect pharmacologically induced changes in coronary arterial flow and can reliably distinguish between those subjects with normal and abnormal coronary artery flow reserve.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.93.8.1502

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Hundley, W. G., Lange, R. A., Clarke, G. D., Meshack, B. M., Payne, J., Landau, C., McColl, R., Sayad, D. E., Willett, D. L., Willard, J. E., Hillis, L. D., & Peshock, R. M.
Venue
Circulation
Published
1996-04-15
Volume
93
Issue
8
Pages
1502-1508
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2040049417
Cited by
161
References
1
FWCI
18.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Coronary Arterial Flow and Flow Reserve in Humans With Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1161/01.cir.93.8.1502
The paper
Hundley, W. G., Lange, R. A., Clarke, G. D., Meshack, B. M., Payne, J., Landau, C., McColl, R., Sayad, D. E., Willett, D. L., Willard, J. E., Hillis, L. D., & Peshock, R. M. (1996). Assessment of Coronary Arterial Flow and Flow Reserve in Humans With Magnetic Resonance Imaging. Circulation. https://doi.org/10.1161/01.cir.93.8.1502

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.