Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 190

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Radiofrequency Current Catheter Ablation of Accessory Atrioventricular Pathways in Ebstein's Anomaly

Cappato, Riccardo, Schlu¨ter, Michael, Weiß, Christian, Antz, Matthias, Koschyk, Dietmar H., Hofmann, Thomas, Kuck, Karl-Heinz · 1996 · Circulation

Abstract

Background In patients with Ebstein's anomaly, localization of accessory pathways (APs) may be impeded by abnormal local electrograms recorded along the atrialized right ventricle and by the presence of multiple APs. The impact of these factors on radiofrequency (RF) current catheter ablation of APs has not been evaluated yet. Methods and Results Twenty-one patients with Ebstein's anomaly and reentrant atrioventricular tachycardias underwent electrophysiological evaluation and subsequent attempts at RF catheter ablation. Thirty-four right-sided APs were found, with 30 located along the atrialized ventricle. Local electrograms in this region were normal in 10 patients but fragmented in 11. Fragmented electrograms prevented the clear distinction between atrial and ventricular activation potentials as well as the identification of AP potentials. Right coronary artery mapping was performed in 7 patients. Abolition of all 26 APs was achieved in the 10 patients with normal local electrograms and in 6 of 11 patients with abnormal electrograms. Right coronary artery mapping allowed AP localization and ablation in 5 patients. In the 5 patients with abnormal electrograms and a total of 8 APs, 6 APs could not be ablated. Unsuccessfully treated patients received antiarrhythmic drugs. During 22±12 months of follow-up, 5 patients had clinical recurrences, including 4 who had undergone a successful RF procedure. Conclusions In patients with Ebstein's anomaly and reentrant atrioventricular tachycardias, factors likely to account for failure of RF catheter ablation include an AP located along the atrialized right ventricle and the abnormal morphology of endocardial activation potentials generated in this region.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.94.3.376

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 190

Metadata

Authors
Cappato, R., Schlu¨ter, M., Weiß, C., Antz, M., Koschyk, D. H., Hofmann, T., & Kuck, K.-H.
Venue
Circulation
Published
1996-08
Volume
94
Issue
3
Pages
376-383
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2017977690
Cited by
190
References
1
FWCI
2.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.