Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 276

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Para-Hisian Pacing: A New Method for Differentiating Retrograde Conduction Over an Accessory AV Pathway From Conduction Over the AV Node

Hirao, Kenzo, Otomo, Kenichiro, Wang, Xunzhang, Beckman, Karen J., McClelland, James H., Widman, Lawrence, Gonzalez, Mario D., Arruda, Mauricio, Nakagawa, Hiroshi, Lazzara, Ralph, Jackman, Warren M.·1996·Circulation

Abstract

Background Differentiation between ventriculoatrial (VA) conduction over an accessory AV pathway (AP) and the AV node (AVN) may be difficult, especially in patients with a septal AP. Methods and Results A new pacing method, para-Hisian pacing, was tested in 149 patients with AP and 53 patients without AP who had AV nodal reentrant tachycardia (AVNRT). Ventricular pacing was performed adjacent to the His bundle and proximal right bundle branch (HB-RB), initially at high output to capture both RV and HB-RB. The output was then decreased to lose HB-RB capture. The change in timing and sequence of retrograde atrial activation between HB-RB capture and noncapture was examined. Loss of HB-RB capture without change in stimulus-atrial (S-A) interval or atrial activation sequence indicated exclusive retrograde AP conduction. An increase in S-A interval without change in His bundle-atrial interval or atrial activation sequence indicated exclusive retrograde AVN conduction. A change in atrial activation sequence indicated the presence of both retrograde AP and AVN conduction. Para-Hisian pacing correctly identified retrograde AP conduction in 132 of 147 AP patients, including all septal and right free wall APs. Retrograde AVN conduction masked AP conduction in 9 of 34 patients with a left free wall AP and 6 of 9 patients with the permanent form of junctional reciprocating tachycardia. Para-Hisian pacing correctly excluded AP conduction in all 53 patients with AVNRT. Conclusions Para-Hisian pacing reliably identifies retrograde conduction over septal and right free wall APs, but AVN conduction may mask APs located far from the pacing site or with a long retrograde conduction time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.94.5.1027

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 276

Metadata

Authors
Hirao, K., Otomo, K., Wang, X., Beckman, K. J., McClelland, J. H., Widman, L., Gonzalez, M. D., Arruda, M., Nakagawa, H., Lazzara, R., & Jackman, W. M.
Venue
Circulation
Published
1996-09
Volume
94
Issue
5
Pages
1027-1035
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2062248589
Cited by
276
References
16
FWCI
2.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Para-Hisian Pacing: A New Method for Differentiating Retrograde Conduction Over an Accessory AV Pathway From Conduction Over the AV Node. https://app.cochat.ai/papers/10.1161/01.cir.94.5.1027
The paper
Hirao, K., Otomo, K., Wang, X., Beckman, K. J., McClelland, J. H., Widman, L., Gonzalez, M. D., Arruda, M., Nakagawa, H., Lazzara, R., & Jackman, W. M. (1996). Para-Hisian Pacing: A New Method for Differentiating Retrograde Conduction Over an Accessory AV Pathway From Conduction Over the AV Node. Circulation. https://doi.org/10.1161/01.cir.94.5.1027

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.