Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 229

The DOI matches its Crossref record.

AREVA: Multicenter Randomized Comparison of Low-Dose Versus Standard-Dose Anticoagulation in Patients With Mechanical Prosthetic Heart Valves

Acar, Jean, Iung, Bernard, Boissel, Jean Pierre, Samama, Michel Meyer, Michel, Pierre Louis, Teppe, Jean Paul, Pony, Jean Claude, Le Breton, Herve´, Thomas, Daniel, Isnard, Richard, de Gevigney, Guy, Viguier, Emmanuelle, Sfihi, Ali, Hanania, Guy, Ghannem, Mohamed, Mirode, Ali, Nemoz, Chantal·1996·Circulation

Abstract

Background Moderate anticoagulation may be proposed to reduce the risk of hemorrhage for certain patients with a mechanical prosthesis, but the consequences for risk of thromboembolism are debated. Methods and Results The purpose of the AREVA trial was to compare moderate oral anticoagulation (international normalized ratio [INR] of 2.0 to 3.0) with the usual regimen (INR of 3.0 to 4.5) after a single-valve replacement with a mechanical prosthesis, either Omnicarbon or St Jude. Patients included were between 18 and 75 years old, in sinus rhythm, and with a left atrial diameter ≤50 mm on the time-motion echocardiogram. Patients were randomized for INR after surgery. From 1991 to 1994, 433 patients underwent valve replacement (aortic, 414; mitral, 19) with 353 St Jude and 80 Omnicarbon prostheses; 380 patients were randomized for INR: 188 for INR 2.0 to 3.0 and 192 for INR 3.0 to 4.5. Mean follow-up was 2.2 years (1 to 4 years). Analysis of 18 001 INR samples showed that the mean of the median of INR was 2.74±0.35 in the 2.0 to 3.0 group and 3.21±0.33 in the 3.0 to 4.5 group ( P <.0001). Thromboembolic events, as assessed from clinical data and CT brain scans, occurred in 10 patients in the 2.0 to 3.0 INR group and 9 patients in the 3.0 to 4.5 INR group ( P =.78). Hemorrhagic events occurred in 34 patients in the 2.0 to 3.0 INR group and 56 patients in the 3.0 to 4.5 INR group ( P <.01), with 13 and 19 major hemorrhagic events, respectively ( P =.29). Conclusions In selected patients with mechanical prostheses, moderate anticoagulation prevents thromboembolic events as effectively as conventional anticoagulation and reduces the incidence of hemorrhagic events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.94.9.2107

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 229

Metadata

Authors
Acar, J., Iung, B., Boissel, J. P., Samama, M. M., Michel, P. L., Teppe, J. P., Pony, J. C., Le Breton, H., Thomas, D., Isnard, R., de Gevigney, G., Viguier, E., Sfihi, A., Hanania, G., Ghannem, M., Mirode, A., & Nemoz, C.
Venue
Circulation
Published
1996-11
Volume
94
Issue
9
Pages
2107-2112
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2048108670
Cited by
229
References
0
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: AREVA: Multicenter Randomized Comparison of Low-Dose Versus Standard-Dose Anticoagulation in Patients With Mechanical Prosthetic Heart Valves. https://app.cochat.ai/papers/10.1161/01.cir.94.9.2107
The paper
Acar, J., Iung, B., Boissel, J. P., Samama, M. M., Michel, P. L., Teppe, J. P., Pony, J. C., Le Breton, H., Thomas, D., Isnard, R., de Gevigney, G., Viguier, E., Sfihi, A., Hanania, G., Ghannem, M., Mirode, A., & Nemoz, C. (1996). AREVA: Multicenter Randomized Comparison of Low-Dose Versus Standard-Dose Anticoagulation in Patients With Mechanical Prosthetic Heart Valves. Circulation. https://doi.org/10.1161/01.cir.94.9.2107

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.