CoChat

Effect of the Direct Nitric Oxide Donors Linsidomine and Molsidomine on Angiographic Restenosis After Coronary Balloon Angioplasty: The ACCORD Study

Lablanche, Jean-Marc, Grollier, Gilles, Lusson, Jean-Rene´, Bassand, Jean-Pierre, Drobinski, Ge´rard, Bertrand, Bernard, Battaglia, Salvatore, Desveaux, Bernard, Juillie`re, Yves, Juliard, Jean-Michel, Metzger, Jean-Philippe, Coste, Pierre, Quiret, Jean-Claude, Dubois-Rande´, Jean-Luc, Crochet, Pierre Dominique, Letac, Brice, Boschat, Jacques, Virot, Patrice, Finet, Ge´rard, Le Breton, Herve´, Livarek, Bernard, Leclercq, Florence, Be´ard, Thierry, Giraud, Thierry, McFadden, Euge`ne P., Bertrand, Michel E. · 1997 · Circulation
Cited by 110

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background Nitric oxide (NO) donors, in addition to their vasodilator effect, decrease platelet aggregation and inhibit vascular smooth muscle cell proliferation. These actions could have beneficial effects on restenosis after coronary balloon angioplasty. Methods and Results In a prospective multicenter, randomized trial, 700 stable coronary patients scheduled for angioplasty received direct NO donors (infusion of linsidomine followed by oral molsidomine) or oral diltiazem. Treatment was started before angioplasty and continued until 12 to 24 hours before follow-up angiography at 6 months. The primary study end point was minimal lumen diameter, assessed by quantitative coronary angiography, 6 months after balloon angioplasty. Clinical variables were well matched in both groups. However, despite intracoronary administration of isosorbide dinitrate, the reference diameter in the NO donor group was significantly greater than in the diltiazem group on the preangioplasty, postangioplasty, and follow-up angiograms. Pretreatment with an NO donor was associated with a modest improvement in the immediate angiographic result compared with pretreatment with diltiazem (minimum luminal diameter, 1.94 versus 1.81 mm;P=.001); this improvement was maintained at the 6-month angiographic follow-up (minimal lumen diameter, 1.54 versus 1.38 mm;P=.007). The extent of late luminal narrowing did not differ significantly between groups (loss index in the NO donor and diltiazam groups, 0.35±0.78 and 0.46±0.74, respectively;P=.103). Restenosis, defined as a binary variable (≥50% stenosis), occurred less often in the NO donor group (38.0% versus 46.5%;P=.026). Combined major clinical events (death, nonfatal myocardial infarction, and coronary revascularization) were similar in the two groups (32.2% versus 32.4%). Conclusions Treatment with linsidomine and molsidomine was associated with a modest improvement in the long-term angiographic result after angioplasty but had no effect on clinical outcome. The improved angiographic result related predominantly to a better immediate procedural result, because late luminal loss did not differ significantly between groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.95.1.83

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 110

Metadata

Authors
Lablanche, J.-M., Grollier, G., Lusson, J.-R., Bassand, J.-P., Drobinski, G., Bertrand, B., Battaglia, S., Desveaux, B., Juillie`re, Y., Juliard, J.-M., Metzger, J.-P., Coste, P., Quiret, J.-C., Dubois-Rande´, J.-L., Crochet, P. D., Letac, B., Boschat, J., Virot, P., Finet, G., Le Breton, H., Livarek, B., Leclercq, F., Be´ard, T., Giraud, T., McFadden, E. P., & Bertrand, M. E.
Venue
Circulation
Published
1997-01-07
Volume
95
Issue
1
Pages
83-89
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1970729969
Cited by
110
References
1
FWCI
13.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of the Direct Nitric Oxide Donors Linsidomine and Molsidomine on Angiographic Restenosis After Coronary Balloon Angioplasty: The ACCORD Study. https://app.cochat.ai/papers/10.1161/01.cir.95.1.83
The paper
Lablanche, J.-M., Grollier, G., Lusson, J.-R., Bassand, J.-P., Drobinski, G., Bertrand, B., Battaglia, S., Desveaux, B., Juillie`re, Y., Juliard, J.-M., Metzger, J.-P., Coste, P., Quiret, J.-C., Dubois-Rande´, J.-L., Crochet, P. D., Letac, B., Boschat, J., Virot, P., Finet, G., . . . Bertrand, M. E. (1997). Effect of the Direct Nitric Oxide Donors Linsidomine and Molsidomine on Angiographic Restenosis After Coronary Balloon Angioplasty: The ACCORD Study. Circulation. https://doi.org/10.1161/01.cir.95.1.83

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.