The DOI matches its Crossref record.
TNK-Tissue Plasminogen Activator in Acute Myocardial Infarction: Results of the Thrombolysis in Myocardial Infarction (TIMI) 10A Dose-Ranging Trial
Abstract
Background TNK-tissue plasminogen activator (TNK-TPA) is a genetically engineered variant of TPA, which in experimental models has a slower plasma clearance and greater fibrin specificity and is 80-fold more resistant to plasminogen activator inhibitor-1 than alteplase TPA. Methods and Results The Thrombolysis in Myocardial Infarction (TIMI) 10A trial was a Phase 1, dose-ranging pilot trial designed to evaluate the pharmacokinetics, safety, and efficacy of TNK-TPA in patients with acute myocardial infarction. One hundred thirteen patients with acute ST-segment elevation myocardial infarction presenting within 12 hours and without contraindications to thrombolysis were enrolled and treated with a single bolus of TNK-TPA over 5 to 10 seconds with doses ranging from 5 to 50 mg. TNK-TPA demonstrated a plasma clearance of 151±55 mL/min and a half-life of 17±7 minutes. Comparable values for wild-type TPA are 572±132 mL/min and 3.5±1.4 minutes, respectively. Systemic fibrinogen and plasminogen levels fell by only 3% and 13%, respectively, at 1 hour after TNK-TPA administration. TIMI grade 3 flow at 90 minutes was achieved in 57% to 64% of patients at the 30- to 50-mg doses. Seven patients (6.2%) experienced a major hemorrhage, which occurred at a vascular access site in six patients. Conclusions TNK-TPA has a prolonged half-life so it can be administered as a single bolus. TNK-TPA appears to be very fibrin specific, and the initial patency and safety profiles are encouraging. Further study of this new thrombolytic agent is ongoing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
WRITING COMMITTEE MEMBERS*, O’Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182742cf6 · Cited by 4,725
2013 ACCF/AHA Guideline for the Management of ST-Elevation Myocardial Infarction
O'Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., Franklin, B. A., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.019 · Cited by 2,625
Van de Werf, F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)07403-6 · Cited by 885
Association of Hemoglobin Levels With Clinical Outcomes in Acute Coronary Syndromes
Sabatine, M. S., Morrow, D. A., Giugliano, R. P., Burton, P. B. J., Murphy, S. A., McCabe, C. H., Gibson, C. M., & Braunwald, E. (2005) · Circulation · doi:10.1161/01.cir.0000162477.70955.5f · Cited by 745
Self-citationAntman, E. M., Giugliano, R. P., Gibson, C. M., McCabe, C. H., Coussement, P., Kleiman, N. S., Vahanian, A., Adgey, A. A. J., Menown, I., Rupprecht, H.-J., et al. (1999) · Circulation · doi:10.1161/01.cir.99.21.2720 · Cited by 681
Self-citationRao, S. V., O’Donoghue, M. L., Ruel, M., Rab, T., Tamis-Holland, J. E., Alexander, J. H., Baber, U., Baker, H., Cohen, M. G., Cruz-Ruiz, M., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001309 · Cited by 625
2025 ACC/AHA/ACEP/NAEMSP/SCAI Guideline for the Management of Patients With Acute Coronary Syndromes
Rao, S. V., O’Donoghue, M. L., Ruel, M., Rab, T., Tamis-Holland, J. E., Alexander, J. H., Baber, U., Baker, H., Cohen, M. G., Cruz-Ruiz, M., et al. (2025) · JACC · doi:10.1016/j.jacc.2024.11.009 · Cited by 552
Henry, T. D., Sharkey, S. W., Burke, M. N., Chavez, I. J., Graham, K. J., Henry, C. R., Lips, D. L., Madison, J. D., Menssen, K. M., Mooney, M. R., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.694141 · Cited by 500
ST-segment elevation myocardial infarction
Vogel, B., Claessen, B. E., Arnold, S. V., Chan, D., Cohen, D. J., Giannitsis, E., Gibson, C. M., Goto, S., Katus, H. A., Kerneis, M., et al. (2019) · Nature Reviews Disease Primers · doi:10.1038/s41572-019-0090-3 · Cited by 419
Self-citationRelationship Between TIMI Frame Count and Clinical Outcomes After Thrombolytic Administration
Gibson, C. M., Murphy, S. A., Rizzo, M. J., Ryan, K. A., Marble, S. J., McCabe, C. H., Cannon, C. P., Van de Werf, F., & Braunwald, E. (1999) · Circulation · doi:10.1161/01.cir.99.15.1945 · Cited by 415
Self-citationBarron, H. V., Cannon, C. P., Murphy, S. A., Braunwald, E., & Gibson, C. M. (2000) · Circulation · doi:10.1161/01.cir.102.19.2329 · Cited by 394
Self-citationCannon, C. P., Gibson, C. M., McCabe, C. H., Adgey, A. A. J., Schweiger, M. J., Sequeira, R. F., Grollier, G., Giugliano, R. P., Frey, M., Mueller, H. S., et al. (1998) · Circulation · doi:10.1161/01.cir.98.25.2805 · Cited by 354
Self-citationTanswell, P., Modi, N., Combs, D., & Danays, T. (2002) · Clinical Pharmacokinetics · doi:10.2165/00003088-200241150-00001 · Cited by 298
Self-citationGibson, C. M., Pinto, D. S., Murphy, S. A., Morrow, D. A., Hobbach, H.-P., Wiviott, S. D., Giugliano, R. P., Cannon, C. P., Antman, E. M., & Braunwald, E. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.06.001 · Cited by 285
Self-citation
Metadata
- Authors
- Cannon, C. P., McCabe, C. H., Gibson, C. M., Ghali, M., Sequeira, R. F., McKendall, G. R., Breed, J., Modi, N. B., Fox, N. L., Tracy, R. P., Love, T. W., & Braunwald, E.
- Venue
- Circulation
- Published
- 1997-01-21
- Volume
- 95
- Issue
- 2
- Pages
- 351-356
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2039130243
- Cited by
- 247
- References
- 0
- FWCI
- 18.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.