Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 452

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Configuration of Unipolar Atrial Electrograms During Electrically Induced Atrial Fibrillation in Humans

Konings, Karen T.S., Smeets, Joep L.R.M., Penn, Olaf C., Wellens, Hein J.J., Allessie, Maurits A.·1997·Circulation

Abstract

Background During atrial fibrillation (AF), the atrium is activated by multiple wavelets that continuously change in size and direction. The aim of this study was to correlate the temporal variation in AF electrogram configuration with the varying spatial patterns of activation. Methods and Results In a group of 25 Wolff-Parkinson-White patients undergoing cardiac surgery, the free wall of the right atrium was mapped (244 points) during electrically induced AF. The unipolar electrograms recorded during 4 seconds of AF were classified into four categories: (1) single deflections, (2) short-double potentials, (3) long-double potentials, and (4) fragmented potentials. The proportion of these four types of electrograms during AF was as follows: singles, 77±12%; short-doubles, 7±3%; long-doubles, 10±7%; and fragmented, 6±4%. Electrogram morphology was an indicator for rapid uniform conduction (single potentials; positive predictive value [PPV] of 0.96), collision (short-double potentials; PPV of 0.33), conduction block (long-double potentials; PPV of 0.84), and pivoting points or slow conduction (fragmented potentials; PPV of 0.87). In type I, II, and III AF, the proportion of long-double potentials was 4±2%, 12±3%, and 18±7% ( P <.05); the proportion of fragmented complexes was 2±2%, 6±3%, and 10±4% ( P <.05), respectively. During electrically induced and self-terminating episodes of AF, no preferential anatomic sites for double or fragmented potentials were found in the right atrium. Conclusions The morphology of single unipolar electrograms during AF reflects the occurrence of various specific patterns of conduction. This might be used to differentiate between different types of AF and to identify regions with structural conduction disturbances involved in perpetuation of chronic AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.95.5.1231

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 452

Metadata

Authors
Konings, K. T. S., Smeets, J. L. R. M., Penn, O. C., Wellens, H. J. J., & Allessie, M. A.
Venue
Circulation
Published
1997-03-04
Volume
95
Issue
5
Pages
1231-1241
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2037795360
Cited by
452
References
1
FWCI
5.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Configuration of Unipolar Atrial Electrograms During Electrically Induced Atrial Fibrillation in Humans. https://app.cochat.ai/papers/10.1161/01.cir.95.5.1231
The paper
Konings, K. T. S., Smeets, J. L. R. M., Penn, O. C., Wellens, H. J. J., & Allessie, M. A. (1997). Configuration of Unipolar Atrial Electrograms During Electrically Induced Atrial Fibrillation in Humans. Circulation. https://doi.org/10.1161/01.cir.95.5.1231

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.