Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 300

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Nonsurgical Septal Reduction for Hypertrophic Obstructive Cardiomyopathy: Outcome in the First Series of Patients

Knight, Charles, Kurbaan, Arvinder S., Seggewiss, Hubert, Henein, Michael, Gunning, Mark, Harrington, Derek, Fassbender, Dieter, Gleichmann, Ulrich, Sigwart, Ulrich · 1997 · Circulation

Abstract

Background Some patients with hypertrophic obstructive cardiomyopathy may gain symptomatic relief from a reduction in the extent of obstruction to left ventricular outflow. We present the outcome of the first series of patients treated with an alternative method of gradient reduction using catheter techniques. Methods and Results Eighteen patients were treated with selective intracoronary alcohol injection to induce localized septal infarction. Patients underwent echocardiographic measurement of left ventricular dimensions and Doppler echocardiographic evaluation of left ventricular outflow tract gradients before the procedure, on the first postoperative day, and at a median follow-up of 3 months after the procedure. In addition, patients underwent exercise testing and symptom evaluation before and 3 months after nonsurgical septal reduction. There was a significant reduction in left ventricular outflow tract obstruction after the procedure (preprocedure, 67 mm Hg [95% CI, 48 to 87 mm Hg]; postprocedure, 25 mm Hg [95% CI, 16 to 34 mm Hg]; P =.0006), which persisted at 3-month follow-up (22 mm Hg [95% CI, 12 to 32 mm Hg]; P =.001). This was associated with a significant improvement in symptoms. There was a small but not significant increase in exercise capacity (n=10; preprocedure, 418 seconds [95% CI, 273 to 563 seconds]; postprocedure, 452 seconds [95% CI, 283 to 621 seconds). Left ventricular dimensions were not significantly altered by nonsurgical septal reduction. Conclusions Nonsurgical septal reduction significantly reduces left ventricular outflow tract obstruction and improves symptoms in some patients with hypertrophic obstructive cardiomyopathy. The technique may provide an alternative to surgical myomectomy in selected patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.95.8.2075

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Knight, C., Kurbaan, A. S., Seggewiss, H., Henein, M., Gunning, M., Harrington, D., Fassbender, D., Gleichmann, U., & Sigwart, U.
Venue
Circulation
Published
1997-04-15
Volume
95
Issue
8
Pages
2075-2081
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2094252831
Cited by
300
References
9
FWCI
18.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nonsurgical Septal Reduction for Hypertrophic Obstructive Cardiomyopathy: Outcome in the First Series of Patients. https://app.cochat.ai/papers/10.1161/01.cir.95.8.2075
The paper
Knight, C., Kurbaan, A. S., Seggewiss, H., Henein, M., Gunning, M., Harrington, D., Fassbender, D., Gleichmann, U., & Sigwart, U. (1997). Nonsurgical Septal Reduction for Hypertrophic Obstructive Cardiomyopathy: Outcome in the First Series of Patients. Circulation. https://doi.org/10.1161/01.cir.95.8.2075

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.