CoChat

Low-Energy Cardioversion of Spontaneous Atrial Fibrillation: Immediate and Long-term Results

Lévy, Samuel, Ricard, Philippe, Gueunoun, Max, Yapo, Florence, Trigano, Jacques, Mansouri, Chadia, Paganelli, Franck · 1997 · Circulation
Cited by 111

The DOI matches its Crossref record.

Abstract

Background Recent studies have suggested that induced atrial fibrillation (AF) could be successfully terminated by using a two-catheter electrode system and low energy (<400 V). This study evaluated the efficacy and safety of low-energy cardioversion in spontaneous chronic and paroxysmal AF. Methods and Results Forty-two consecutive patients with spontaneous AF underwent low-energy electrical cardioversion. AF was chronic (≥1 month) with a mean duration of 9±19 months in 28 patients (group I) or paroxysmal with a history of recurrent attacks and a mean duration of the present episode of 7±16 days in 14 patients (group II). An underlying heart disease was present in 28 patients. A 3/3-ms biphasic shock was delivered between catheters positioned in the right atrium and the coronary sinus in 32 patients. In 10 patients, the left pulmonary artery branch was used. The catheters were connected to a custom external defibrillator. The shocks were synchronized to the R wave. Following a test shock of 60 V, the energy was increased in 40-V steps until a maximum of 400 V or restoration of sinus rhythm. Sinus rhythm was restored in 22 of the 28 patients (78%) of group I by using a mean leading-edge voltage of 297±57 V (mean energy, 3.3±1.3 J) and in 11 of 14 patients (78%) of group II by using a mean leading-edge voltage of 223±41 V (mean energy, 1.8±0.7 J). The energy required for terminating chronic AF was significantly ( P <.001) higher than that required for terminating paroxysmal AF. Among the other variables studied, the duration of AF significantly affected the successful voltage. Ventricular proarrhythmia occurred in 1 patient with atrial flutter due to an unsynchronized shock. Of the 22 patients of group I in whom sinus rhythm was restored, 14 (63%) remained in sinus rhythm with a mean follow-up of 9±3 months. Pain level showed a good correlation with increasing voltage. However, a marked interindividual variation was noted. Conclusions Atrial defibrillation using low energy between two intracardiac catheters with an electrical field between the right and left atria and the protocol used is feasible in patients with persistent spontaneous AF. The technique is safe provided synchronization to the R wave is achieved. A low recurrence rate of AF was seen in patients in whom sinus rhythm was restored.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.96.1.253

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Lévy, S., Ricard, P., Gueunoun, M., Yapo, F., Trigano, J., Mansouri, C., & Paganelli, F.
Venue
Circulation
Published
1997-07
Volume
96
Issue
1
Pages
253-259
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2056616312
Cited by
111
References
0
FWCI
10.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.