The DOI matches its Crossref record.
Cardiopulmonary Interactions After Fontan Operations: Augmentation of Cardiac Output Using Negative Pressure Ventilation
Abstract
Background The low-output state is the chief cause of morbidity and mortality after Fontan operations. An alternative hemodynamic tool would be a welcome addition for these patients, who are typically resistant to conventional therapeutic measures. Methods and Results The hemodynamic effects of conversion from conventional intermittent positive pressure ventilation (IPPV) to cuirass negative pressure ventilation (NPV) was investigated in nine acute postoperative Fontan patients on the pediatric intensive care unit and nine anesthetized patients undergoing cardiac catheterization in the convalescent phase after Fontan operations. Pulmonary blood flow was measured using the direct Fick method during IPPV and after a brief period of NPV. In one subgroup of patients, pulmonary blood flow was measured again after reinstitution of IPPV, and in a second subgroup, pulmonary blood flow was measured after an extended period of NPV. A brief period of NPV increased pulmonary blood flow from 2.4 to 3.5 L · min −1 · /m −2 , with a mean increase of 42%. Pulmonary blood flow continued to improve, with a total increase of 54% after an extended period of NPV. Values fell toward baseline after reinstitution of IPPV. Heart rate was unchanged during NPV, and the improvement in pulmonary blood flow was achieved by an increase in stroke volume from 25 mL/m 2 to 37 mL/m. 2 Conclusions Through improvement of the stroke volume alone, NPV brought about a marked increase in the pulmonary blood flow and, hence, cardiac output of Fontan patients. An improvement in cardiac output of this order, and by this mechanism, is currently unmatched by any therapeutic alternatives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kleinman, M. E., Chameides, L., Schexnayder, S. M., Samson, R. A., Hazinski, M. F., Atkins, D. L., Berg, M. D., de Caen, A. R., Fink, E. L., Freid, E. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971101 · Cited by 1,949
European Resuscitation Council Guidelines for Resuscitation 2010 Section 1. Executive summary
Nolan, J. P., Soar, J., Zideman, D. A., Biarent, D., Bossaert, L. L., Deakin, C., Koster, R. W., Wyllie, J., & Böttiger, B. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.021 · Cited by 1,375
Price, L. C., Wort, S. J., Finney, S. J., Marino, P. S., & Brett, S. J. (2010) · Critical Care · doi:10.1186/cc9264 · Cited by 389
European Resuscitation Council Guidelines for Resuscitation 2010 Section 6. Paediatric life support
Biarent, D., Bingham, R., Eich, C., López-Herce, J., Maconochie, I., Rodríguez-Núñez, A., Rajka, T., & Zideman, D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.012 · Cited by 354
Kleinman, M. E., de Caen, A. R., Chameides, L., Atkins, D. L., Berg, R. A., Berg, M. D., Bhanji, F., Biarent, D., Bingham, R., Coovadia, A. H., et al. (2010) · Pediatrics · doi:10.1542/peds.2010-2972a · Cited by 86
Metadata
- Authors
- Shekerdemian, L. S., Bush, A., Shore, D. F., Lincoln, C., & Redington, A. N.
- Venue
- Circulation
- Published
- 1997-12-02
- Volume
- 96
- Issue
- 11
- Pages
- 3934-3942
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W3011080772
- Cited by
- 196
- References
- 0
- FWCI
- 2.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiopulmonary Interactions After Fontan Operations: Augmentation of Cardiac Output Using Negative Pressure Ventilation. https://app.cochat.ai/papers/10.1161/01.cir.96.11.3934
- The paper
- Shekerdemian, L. S., Bush, A., Shore, D. F., Lincoln, C., & Redington, A. N. (1997). Cardiopulmonary Interactions After Fontan Operations: Augmentation of Cardiac Output Using Negative Pressure Ventilation. Circulation. https://doi.org/10.1161/01.cir.96.11.3934
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.