Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record.

Cardiopulmonary Interactions After Fontan Operations: Augmentation of Cardiac Output Using Negative Pressure Ventilation

Shekerdemian, Lara S., Bush, Andrew, Shore, Darryl F., Lincoln, Christopher, Redington, Andrew N. · 1997 · Circulation

Abstract

Background The low-output state is the chief cause of morbidity and mortality after Fontan operations. An alternative hemodynamic tool would be a welcome addition for these patients, who are typically resistant to conventional therapeutic measures. Methods and Results The hemodynamic effects of conversion from conventional intermittent positive pressure ventilation (IPPV) to cuirass negative pressure ventilation (NPV) was investigated in nine acute postoperative Fontan patients on the pediatric intensive care unit and nine anesthetized patients undergoing cardiac catheterization in the convalescent phase after Fontan operations. Pulmonary blood flow was measured using the direct Fick method during IPPV and after a brief period of NPV. In one subgroup of patients, pulmonary blood flow was measured again after reinstitution of IPPV, and in a second subgroup, pulmonary blood flow was measured after an extended period of NPV. A brief period of NPV increased pulmonary blood flow from 2.4 to 3.5 L · min −1 · /m −2 , with a mean increase of 42%. Pulmonary blood flow continued to improve, with a total increase of 54% after an extended period of NPV. Values fell toward baseline after reinstitution of IPPV. Heart rate was unchanged during NPV, and the improvement in pulmonary blood flow was achieved by an increase in stroke volume from 25 mL/m 2 to 37 mL/m. 2 Conclusions Through improvement of the stroke volume alone, NPV brought about a marked increase in the pulmonary blood flow and, hence, cardiac output of Fontan patients. An improvement in cardiac output of this order, and by this mechanism, is currently unmatched by any therapeutic alternatives.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.96.11.3934

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 196

Metadata

Authors
Shekerdemian, L. S., Bush, A., Shore, D. F., Lincoln, C., & Redington, A. N.
Venue
Circulation
Published
1997-12-02
Volume
96
Issue
11
Pages
3934-3942
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W3011080772
Cited by
196
References
0
FWCI
2.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiopulmonary Interactions After Fontan Operations: Augmentation of Cardiac Output Using Negative Pressure Ventilation. https://app.cochat.ai/papers/10.1161/01.cir.96.11.3934
The paper
Shekerdemian, L. S., Bush, A., Shore, D. F., Lincoln, C., & Redington, A. N. (1997). Cardiopulmonary Interactions After Fontan Operations: Augmentation of Cardiac Output Using Negative Pressure Ventilation. Circulation. https://doi.org/10.1161/01.cir.96.11.3934

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.