Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Prospective Evaluation of Catheter Ablation of Ventricular Tachycardia as Adjuvant Therapy in Patients With Coronary Artery Disease and an Implantable Cardioverter-Defibrillator

Strickberger, S. Adam, Man, K. Ching, Daoud, Emile G., Goyal, Rajiva, Brinkman, Karin, Hasse, Carol, Bogun, Frank, Knight, Bradley P., Weiss, Raul, Bahu, Marwan, Morady, Fred · 1997 · Circulation

Abstract

Background Implantable cardioverter-defibrillator (ICD) therapy is integral to current therapy for ventricular tachycardia. Patients with an ICD frequently require concomitant antiarrhythmic drug therapy. Despite this, some patients still receive frequent ICD therapies for ventricular tachycardia. Therefore, the purpose of this prospective study was to determine the utility of ablation of ventricular tachycardia in patients with an ICD who experience frequent ICD therapies. Methods and Results Twenty-one consecutive patients with frequent ICD therapies despite antiarrhythmic drug therapy were the subjects of this study. The mean age was 69±6 years, and 17 were men. The mean ejection fraction was 0.22±0.08, and all patients had coronary artery disease. During the 36±51 days (range, 4 days to 7 months) preceding the ablation procedures, the patients received 34±55 ICD therapies for the clinical ventricular tachycardia, or a mean of 25±88 ICD therapies per month. The patients underwent radiofrequency ablation of the presumed clinical ventricular tachycardia by inducing the tachycardia and mapping according to endocardial activation, continuous electrical activity, pace mapping, concealed entrainment, or mid-diastolic potentials. Ablation of the clinical arrhythmia was successful in 76% of patients during 1.4±0.6 (range, 1 to 3) ablation procedures and required 12.5±9.2 applications of energy. During 11.8±10.0 months of follow-up, the frequency of ICD therapies per month decreased from 60±80 before successful ablation to 0.1±0.3 ICD therapies per month after ablation ( P =.01). A quality-of-life assessment demonstrated a significant improvement after successful ( P =.02) but not unsuccessful ablation ( P =.9). Conclusions Radiofrequency ablation of ventricular tachycardia as adjuvant therapy in patients with coronary artery disease and an ICD has a reasonable success rate, significantly reduces ICD therapies, and appears to be associated with an improved quality of life.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.96.5.1525

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
Strickberger, S. A., Man, K. C., Daoud, E. G., Goyal, R., Brinkman, K., Hasse, C., Bogun, F., Knight, B. P., Weiss, R., Bahu, M., & Morady, F.
Venue
Circulation
Published
1997-09-02
Volume
96
Issue
5
Pages
1525-1531
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2091296447
Cited by
165
References
1
FWCI
10.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Prospective Evaluation of Catheter Ablation of Ventricular Tachycardia as Adjuvant Therapy in Patients With Coronary Artery Disease and an Implantable Cardioverter-Defibrillator. https://app.cochat.ai/papers/10.1161/01.cir.96.5.1525
The paper
Strickberger, S. A., Man, K. C., Daoud, E. G., Goyal, R., Brinkman, K., Hasse, C., Bogun, F., Knight, B. P., Weiss, R., Bahu, M., & Morady, F. (1997). A Prospective Evaluation of Catheter Ablation of Ventricular Tachycardia as Adjuvant Therapy in Patients With Coronary Artery Disease and an Implantable Cardioverter-Defibrillator. Circulation. https://doi.org/10.1161/01.cir.96.5.1525

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.