Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 187

The DOI matches its Crossref record.

Evaluation of the Spatial Aspects of T-Wave Complexity in the Long-QT Syndrome

Priori, Silvia G., Mortara, David W., Napolitano, Carlo, Diehl, Livia, Paganini, Vincenzo, Cantù, Francesco, Cantù, Giacomo, Schwartz, Peter J. · 1997 · Circulation

Abstract

Background The duration of the QT interval is only a gross estimate of repolarization. Besides its limited accuracy and reproducibility, it does not provide information on the morphology of the T wave; thus, morphologic alterations such as notches can be only qualitatively described but not objectively quantified. Methods and Results To measure the complexity of repolarization in the long-QT syndrome (LQTS) patients, we previously applied principal component analysis to body surface mapping and found it useful in distinguishing normal from abnormal repolarization patterns (sensitivity, 87%). In the present study, we applied principal component analysis to 12-lead Holter recordings. The index of complexity of repolarization that we have developed (CR 24h ) reflects the average 24-hour complexity of repolarization and is mathematically defined as the average ratio between the second and the first eigenvalue. We studied 36 LQTS patients and 40 control subjects. A mean of 22±1.3 ECG recordings at 1-hour intervals was used in each patient, and a total of 1655 recordings were analyzed. CR 24h was significantly higher in LQTS than in control subjects (34±12% versus 13±3%; P <.0001). A CR 24h exceeding 2 SD above the mean of the control group (>20%) was present in 32 of 36 patients (88%). The negative predictive value of CR 24h in LQTS was 88%, and the combination of prolonged QT and abnormal CR 24h identified all LQTS patients from normal subjects, including 4 affected symptomatic individuals with a normal QT interval duration, suggesting that CR 24h provides information independent of QT duration. Conclusions Our data suggest that principal component analysis applied to 24-hour, 12-lead Holter recording adequately quantifies the complexity of ventricular repolarization and may become a useful noninvasive diagnostic tool in LQTS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.96.9.3006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 187

Metadata

Authors
Priori, S. G., Mortara, D. W., Napolitano, C., Diehl, L., Paganini, V., Cantù, F., Cantù, G., & Schwartz, P. J.
Venue
Circulation
Published
1997-11-04
Volume
96
Issue
9
Pages
3006-3012
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2053641999
Cited by
187
References
0
FWCI
6.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the Spatial Aspects of T-Wave Complexity in the Long-QT Syndrome. https://app.cochat.ai/papers/10.1161/01.cir.96.9.3006
The paper
Priori, S. G., Mortara, D. W., Napolitano, C., Diehl, L., Paganini, V., Cantù, F., Cantù, G., & Schwartz, P. J. (1997). Evaluation of the Spatial Aspects of T-Wave Complexity in the Long-QT Syndrome. Circulation. https://doi.org/10.1161/01.cir.96.9.3006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.