The DOI matches its Crossref record.
Empirical Versus Tested Antitachycardia Pacing in Implantable Cardioverter Defibrillators: A Prospective Study Including 200 Patients
Open accessAbstract
Background —Implantable cardioverter-defibrillators (ICDs) reduce the risk of sudden cardiac death. The objective of this study was to evaluate whether testing of antitachycardia pacing (ATP) for induced ventricular tachycardias (VTs) at predischarge examination can predict ATP success during follow-up. Methods and Results —The study covers 200 consecutive patients who received ICD implants from June 1991 through December 1995. All underwent electrophysiological testing. In 54 patients (ATP tested, group T), ATP terminated induced VTs successfully. In 146 patients (empirically programmed ATP, group E), only ventricular fibrillation could be induced, including 18 with unsuccessful ATP attempts for induced VTs. Disregarding the results of ATP testing, the same ATP scheme was programmed in all patients: three attempts of autodecremental ramp with 81% of the VT cycle length, with 8 to 10 pulses. During a follow-up of 20.4±10 months, 95% of 3819 spontaneous VTs were successfully terminated with ATP in 42 patients of group T. In group E, 90% of 1346 spontaneous VTs in 81 patients were terminated with ATP. Acceleration after ATP occurred in 2% in group T versus 5% in group E. The success for all episodes in individual patients was ≥90% in >60% of the ATP tested and empirically programmed patients. Conclusions —The results of this 200-patient prospective study comparing tested versus empirical ATP show high success (95% versus 90%) for VT termination, with low rates of acceleration. ATP is safe and very effective and should be programmed “on” in all patients regardless of the predischarge EP inducibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Maron, B. J., Shen, W.-K., Link, M. S., Epstein, A. E., Almquist, A. K., Daubert, J. P., Bardy, G. H., Favale, S., Rea, R. F., Boriani, G., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002103420601 · Cited by 832
Tracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 552
Metadata
- Authors
- Schaumann, A., Mühlen, F. V. Z., Herse, B., Gonska, B.-D., & Kreuzer, H.
- Venue
- Circulation
- Published
- 1998-01-13
- Volume
- 97
- Issue
- 1
- Pages
- 66-74
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2022153462
- Cited by
- 160
- References
- 0
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Empirical Versus Tested Antitachycardia Pacing in Implantable Cardioverter Defibrillators: A Prospective Study Including 200 Patients. https://app.cochat.ai/papers/10.1161/01.cir.97.1.66
- The paper
- Schaumann, A., Mühlen, F. V. Z., Herse, B., Gonska, B.-D., & Kreuzer, H. (1998). Empirical Versus Tested Antitachycardia Pacing in Implantable Cardioverter Defibrillators: A Prospective Study Including 200 Patients. Circulation. https://doi.org/10.1161/01.cir.97.1.66
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.