Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 809

The DOI matches its Crossref record.

Microbubbles Targeted to Intercellular Adhesion Molecule-1 Bind to Activated Coronary Artery Endothelial Cells

Open access
Villanueva, Flordeliza S., Jankowski, Ron J., Klibanov, Sasha, Pina, Maris L., Alber, Sean M., Watkins, Simon C., Brandenburger, Gary H., Wagner, William R.·1998·Circulation

Abstract

Background —Preclinical atherosclerosis is associated with increased endothelial cell (EC) expression of leukocyte adhesion molecules (LAMs), which mediate monocyte adhesion during atherogenesis. Identification of cell-surface LAMs may uniquely allow assessment of endothelial function, but there are no in vivo methods for detecting LAMs. We tested a new microbubble designed to bind to and allow specific ultrasound detection of intercellular adhesion molecule-1 (ICAM-1). Methods and Results —A perfluorobutane gas–filled lipid-derived microsphere with monoclonal antibody to ICAM-1 covalently bound to the bubble shell was synthesized. Bubbles with either nonspecific IgG or no protein on the shell were synthesized as controls. Coverslips of cultured human coronary artery ECs were placed in a parallel-plate perfusion chamber and exposed to 1 of the 3 microbubble species, followed by perfusion with culture medium. Experiments were performed with either normal or interleukin-1β–activated ECs overexpressing ICAM-1, and bubble adherence was quantified with epifluorescent videomicroscopy. There was limited adherence of control bubbles to normal or activated ECs, whereas a 40-fold increase in adhesion occurred when anti–ICAM-1–conjugated bubbles were exposed to activated ECs compared with normal ECs (8.1±3.5 versus 0.21±0.09 bubbles per cell, respectively, P <0.001). Although diminished, this difference persisted even after perfusion at higher wall shear rates. Conclusions —A gas-filled microbubble with anti–ICAM-1 antibody on its shell specifically binds to activated ECs overexpressing ICAM-1. Diagnostic ultrasound in conjunction with targeted contrast agents has the unique potential to characterize cell phenotype in vivo.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.1.1

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 809

Metadata

Authors
Villanueva, F. S., Jankowski, R. J., Klibanov, S., Pina, M. L., Alber, S. M., Watkins, S. C., Brandenburger, G. H., & Wagner, W. R.
Venue
Circulation
Published
1998-07-07
Volume
98
Issue
1
Pages
1-5
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2034373812
Cited by
809
References
0
FWCI
105.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microbubbles Targeted to Intercellular Adhesion Molecule-1 Bind to Activated Coronary Artery Endothelial Cells. https://app.cochat.ai/papers/10.1161/01.cir.98.1.1
The paper
Villanueva, F. S., Jankowski, R. J., Klibanov, S., Pina, M. L., Alber, S. M., Watkins, S. C., Brandenburger, G. H., & Wagner, W. R. (1998). Microbubbles Targeted to Intercellular Adhesion Molecule-1 Bind to Activated Coronary Artery Endothelial Cells. Circulation. https://doi.org/10.1161/01.cir.98.1.1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.