Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 160

The DOI matches its Crossref record.

Gross and Microscopic Pathological Changes Associated With Nonthoracotomy Implantable Defibrillator Leads

Open access
Epstein, Andrew E., Kay, G. Neal, Plumb, Vance J., Dailey, Sharon M., Anderson, Peter G. · 1998 · Circulation

Abstract

Background—Although the effects of epicardial implantable cardioverter-defibrillator (ICD) leads on underlying cardiac tissue have been reported, the gross and microscopic changes associated with endocardial ICD leads are less well described. This study describes the gross and microscopic changes associated with endocardial ICD leads in humans. Methods and Results—The hearts from 8 patients were examined. At the time of ICD implantation, the patients’ mean age was 47±11 years, and the left ventricular ejection fraction was 0.24±0.10. Four patients had ischemic heart disease, and 4 had dilated cardiomyopathy. Five hearts were examined after transplantation; 3, after death. The electrode-myocardial interfaces were characterized by intense endocardial fibrosis and were remarkably consistent. Each lead was encased by a ring of fibroelastic tissue, and there was fibrosis of the right ventricular myocardium adjacent to the leads. Fibrosis involved the tricuspid valve in 5 patients, and 1 had perforation of the valve by the lead. Microscopically, interstitial fibrosis was adjacent to each lead in the current path of ICD shocks. Acute cell injury was present only in the hearts that had received recent shocks. Conclusions—The ICD electrode-myocardial interface is characterized by intense fibrosis. The fibrosis associated with endocardial ICD leads and the cumulative acute damage produced by defibrillation discharges may explain changes in the defibrillation and pacing thresholds and the difficulty of lead extraction that can be encountered with transvenous ICD systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.15.1517

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Epstein, A. E., Kay, G. N., Plumb, V. J., Dailey, S. M., & Anderson, P. G.
Venue
Circulation
Published
1998-10-13
Volume
98
Issue
15
Pages
1517-1524
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2119048534
Cited by
160
References
0
FWCI
3.22
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gross and Microscopic Pathological Changes Associated With Nonthoracotomy Implantable Defibrillator Leads. https://app.cochat.ai/papers/10.1161/01.cir.98.15.1517
The paper
Epstein, A. E., Kay, G. N., Plumb, V. J., Dailey, S. M., & Anderson, P. G. (1998). Gross and Microscopic Pathological Changes Associated With Nonthoracotomy Implantable Defibrillator Leads. Circulation. https://doi.org/10.1161/01.cir.98.15.1517

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.