Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 246

The DOI matches its Crossref record.

Localization of Optimal Ablation Site of Idiopathic Ventricular Tachycardia from Right and Left Ventricular Outflow Tract by Body Surface ECG

Kamakura, Shiro, Shimizu, Wataru, Matsuo, Kiyotaka, Taguchi, Atsushi, Suyama, Kazuhiro, Kurita, Takashi, Aihara, Naohiko, Ohe, Tohru, Shimomura, Katsuro · 1998 · Circulation

Abstract

Background —Idiopathic ventricular tachycardia (VT) is known to arise from the right ventricular (RV) and left ventricular outflow tracts (LVOT). However, reliable noninvasive methods to localize the optimum ablation site for VT have not been reported. Methods and Results —Body surface maps (BSM) and 12-lead ECGs were investigated in 35 VTs from the RVOT and 5 VTs from the LVOT in which the origin was confirmed during the ablation procedure. The RVOT was classified into 8 subdivisions with the use of a 3-dimensional anatomic relation: anterior (A)–posterior (P), right (R)–left (L), and superior (S)–inferior (I). On the BSM, the following 3 indexes differentiated each location of the origin, with a diagnostic accuracy of 88% (A-P), 92% (R-L), and 77% (S-I): (1) the location of the minimum at the early-to-mid QRS (right, A; left, P), (2) the isopotential distribution in the left shoulder area after 30 ms of QRS (positive, R; negative, L), and (3) the downward moving time of the minimum at the early-to-mid QRS (≥50 ms, S; <50 ms, I). On the 12-lead ECG, (1) the QRS duration (>140 ms, A; ≤140 ms, P) and the R-wave pattern in leads II and III (RR’ or Rr’, A, R, P), (2) the QS wave amplitude in aVR and aVL (aVR≥aVL, R; aVR<aVL, L), and (3) the r-wave amplitude in V 1 and V 2 (high, S; low, I) localized the origin with 80%, 86% (A-P), 80% (R-L), and 66% (S-I) accuracy. R/S≥1 in lead V 3 was an index suggesting the LVOT origin. Conclusions —The origin or the optimum ablation site of idiopathic VT from RVOT and LVOT can be localized with the use of indexes obtained with a BSM or 12-lead ECG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.15.1525

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 246

Metadata

Authors
Kamakura, S., Shimizu, W., Matsuo, K., Taguchi, A., Suyama, K., Kurita, T., Aihara, N., Ohe, T., & Shimomura, K.
Venue
Circulation
Published
1998-10-13
Volume
98
Issue
15
Pages
1525-1533
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1964888880
Cited by
246
References
0
FWCI
3.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Localization of Optimal Ablation Site of Idiopathic Ventricular Tachycardia from Right and Left Ventricular Outflow Tract by Body Surface ECG. https://app.cochat.ai/papers/10.1161/01.cir.98.15.1525
The paper
Kamakura, S., Shimizu, W., Matsuo, K., Taguchi, A., Suyama, K., Kurita, T., Aihara, N., Ohe, T., & Shimomura, K. (1998). Localization of Optimal Ablation Site of Idiopathic Ventricular Tachycardia from Right and Left Ventricular Outflow Tract by Body Surface ECG. Circulation. https://doi.org/10.1161/01.cir.98.15.1525

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.