Pulmonary Vein Stenosis After Catheter Ablation of Atrial Fibrillation
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background —This report describes the complication of pulmonary vein stenosis with resultant severe pulmonary hypertension that developed in 2 patients after successful catheter ablation of chronic atrial fibrillation. Methods and Results —Three months after successful catheter ablation of atrial fibrillation, both patients developed progressive dyspnea and pulmonary hypertension. Both were found to have severe stenosis of all 4 pulmonary veins near the junction with the left atrium. Balloon dilation of the stenotic pulmonary veins was performed in these patients, with improvement in dyspnea and pulmonary hypertension. Conclusions —The complication of pulmonary vein stenosis is potentially life-threatening, and the application of radiofrequency current within the pulmonary veins with standard catheter technology should be avoided. This complication can be treated with balloon dilation, although the long-term course is unknown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Focal Source of Atrial Fibrillation Treated by Discrete Radiofrequency Ablation
Jai¨s, P., Hai¨ssaguerre, M., Shah, D. C., Chouairi, S., Gencel, L., Hocini, M., & Cle´menty, J. (1997) · Circulation · doi:10.1161/01.cir.95.3.572 · Cited by 1,117
Right and Left Atrial Radiofrequency Catheter Therapy of Paroxysmal Atrial Fibrillation
HAÍSSAGUERRE, M., JAÍS, P., SHAH, D. C., GENCEL, L., PRADEAU, V., GARRIGUES, S., CHOUAIRI, S., HOCINI, M., LE MÉTAYER, P., ROUDAUT, R., et al. (1996) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1996.tb00492.x · Cited by 577
Successful Catheter Ablation of Atrial Fibrillation
HAÏSSAGUERRE, M., GENCEL, L., FISCHER, B., LE MÉTAYER, P., POQUET, F., MARCUS, F. I., & CLEMÉNTY, J. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01146.x · Cited by 334
Radiofrequency Catheter Ablation in Unusual Mechanisms of Atrial Fibrillation: Report of Three Cases
HAÏSSAGUERRE, M., MARCUS, F. I., FISCHER, B., & CLÉMENTY, J. (1994) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1994.tb01197.x · Cited by 231
Radiofrequency catheter ablation of left lateral accessory pathways via the coronary sinus.
Haı̈ssaguerre, M., Gaïta, F., Fischer, B., Egloff, P., Lemétayer, P., & Warin, J. F. (1992) · Circulation · doi:10.1161/01.cir.86.5.1464 · Cited by 136
Huang, S. K. S., Graham, A. R., Bharati, S., Lee, M. A., Gorman, G., & Lev, M. (1988) · Circulation · doi:10.1161/01.cir.78.2.416 · Cited by 99
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Metadata
- Authors
- Robbins, I. M., Colvin, E. V., Doyle, T. P., Kemp, W. E., Loyd, J. E., McMahon, W. S., & Kay, G. N.
- Venue
- Circulation
- Published
- 1998-10-27
- Volume
- 98
- Issue
- 17
- Pages
- 1769-1775
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2011347240
- Cited by
- 443
- References
- 6
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.