CoChat

Heterogeneous Atrial Denervation Creates Substrate for Sustained Atrial Fibrillation

Open access
Olgin, Jeffrey E., Sih, Haris J., Hanish, Steven, Jayachandran, J. Vijay, Wu, Jiashin, Zheng, Qi Huang, Winkle, Wendy, Mulholland, G. Keith, Zipes, Douglas P., Hutchins, Gary · 1998 · Circulation
Cited by 125

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background —Heterogeneous electrophysiological properties, which may be due in part to autonomic innervation, are important in the maintenance of atrial fibrillation (AF). We hypothesized that heterogeneous sympathetic denervation with phenol would create a milieu for sustained AF. Methods and Results —After the determination of baseline inducibility, 15 dogs underwent atrial epicardial phenol application and 11 underwent a sham procedure. After 2 weeks of recovery, the animals had repeat attempts at inducing AF and effective refractory period (ERP) testing. Epicardial maps were obtained to determine local AF cycle lengths. ERPs were determined at baseline and during sympathetic, vagal, and simultaneous vagal/sympathetic stimulation. Dogs then underwent PET imaging with either a sympathetic ([ 11 C]hydroxyephedrine, HED) or parasympathetic (5-[ 11 C]methoxybenzovesamicol, MOBV) nerve label. None of the animals had sustained AF (>60 minutes) at baseline. None of the sham dogs and 14 of 15 phenol dogs had sustained AF at follow-up. Sites to which phenol was applied had a significantly shorter ERP (136±17.6 ms) than those same sites in the sham controls (156±19.1 ms) ( P =0.01). Although there was no difference in the ERP change with either vagal or sympathetic stimulation alone between phenol and nonphenol sites, the percent decrease in ERP with simultaneous vagal/sympathetic stimulation was greater in the phenol sites (17±8%) than in the nonphenol sites (9±9%) ( P =0.01). There was a significantly increased dispersion of refractoriness (21±6.4 ms in the sham versus 58±14 ms in the phenol dogs, P =0.01) as well as dispersion of AF cycle length (49±10 ms in the sham versus 105±12 ms in the phenol dogs, P =0.0001). PET images demonstrated defects of HED uptake in the areas of phenol application, with no defect of MOBV uptake. Conclusions —Heterogeneous sympathetic atrial denervation with phenol facilitates sustained AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.23.2608

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 125

Metadata

Authors
Olgin, J. E., Sih, H. J., Hanish, S., Jayachandran, J. V., Wu, J., Zheng, Q. H., Winkle, W., Mulholland, G. K., Zipes, D. P., & Hutchins, G.
Venue
Circulation
Published
1998-12-08
Volume
98
Issue
23
Pages
2608-2614
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2112929381
Cited by
125
References
1
FWCI
2.97
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heterogeneous Atrial Denervation Creates Substrate for Sustained Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/01.cir.98.23.2608
The paper
Olgin, J. E., Sih, H. J., Hanish, S., Jayachandran, J. V., Wu, J., Zheng, Q. H., Winkle, W., Mulholland, G. K., Zipes, D. P., & Hutchins, G. (1998). Heterogeneous Atrial Denervation Creates Substrate for Sustained Atrial Fibrillation. Circulation. https://doi.org/10.1161/01.cir.98.23.2608

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.