The DOI matches its Crossref record.
Regression of Cellular Hypertrophy After Left Ventricular Assist Device Support
Abstract
Background —Although multiple studies have shown that the left ventricular assist device (LVAD) improves distorted cardiac geometry, the pathological mechanisms of the “reverse remodeling” of the heart are unknown. Our goal was to determine the effects of LVAD support on cardiac myocyte size and shape. Methods and Results —Isolated myocytes were obtained at cardiac transplantation from 30 failing hearts (12 ischemic, 18 nonischemic) without LVAD support, 10 failing hearts that received LVAD support for 75±15 days, and 6 nonfailing hearts. Cardiac myocyte volume, length, width, and thickness were determined by use of previously validated techniques. Isolated myocytes from myopathic hearts exhibited increased volume, length, width, and length-to-thickness ratio compared with normal myocytes ( P <0.05). However, there were no differences in any parameter between myocytes from ischemic and nonischemic cardiomyopathic hearts. Long-term LVAD support resulted in a 28% reduction in myocyte volume, 20% reduction in cell length, 20% reduction in cell width, and 32% reduction in cell length-to-thickness ratio ( P <0.05). In contrast, LVAD support was associated with no change in cell thickness. These cellular changes were associated with reductions in left ventricular dilation and left ventricular mass measured echocardiographically in 6 of 10 LVAD-supported patients. Conclusions —These studies suggest that the regression of cellular hypertrophy is a major contributor to the “reverse remodeling” of the heart after LVAD implantation. The favorable alterations in geometry that occur in parallel fashion at both the organ and cellular levels may contribute to reduced wall stress and improved mechanical performance after LVAD support.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Feldman, A. M., & McNamara, D. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011093431908 · Cited by 958
Left Ventricular Assist Device and Drug Therapy for the Reversal of Heart Failure
Birks, E. J., Tansley, P. D., Hardy, J., George, R. S., Bowles, C. T., Burke, M., Banner, N. R., Khaghani, A., & Yacoub, M. H. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa053063 · Cited by 885
Braunwald, E. (2013) · JACC: Heart Failure · doi:10.1016/j.jchf.2012.10.002 · Cited by 730
Cellular basis of abnormal calcium transients of failing human ventricular myocytes
Piacentino, V., Weber, C. R., Chen, X., Weisser-Thomas, J., Margulies, K. B., Bers, D. M., & Houser, S. R. (2003) · Circulation Research · doi:10.1161/01.res.0000062469.83985.9b · Cited by 477
Self-citationFoxO Transcription Factors Promote Autophagy in Cardiomyocytes
Sengupta, A., Molkentin, J. D., & Yutzey, K. E. (2009) · Journal of Biological Chemistry · doi:10.1074/jbc.m109.024406 · Cited by 428
Metadata
- Authors
- Zafeiridis, A., Jeevanandam, V., Houser, S. R., & Margulies, K. B.
- Venue
- Circulation
- Published
- 1998-08-18
- Volume
- 98
- Issue
- 7
- Pages
- 656-662
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2073873067
- Cited by
- 378
- References
- 0
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regression of Cellular Hypertrophy After Left Ventricular Assist Device Support. https://app.cochat.ai/papers/10.1161/01.cir.98.7.656
- The paper
- Zafeiridis, A., Jeevanandam, V., Houser, S. R., & Margulies, K. B. (1998). Regression of Cellular Hypertrophy After Left Ventricular Assist Device Support. Circulation. https://doi.org/10.1161/01.cir.98.7.656
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.