Adverse Events With Transvenous Implantable Cardioverter-Defibrillators: A Prospective Multicenter Study

Rosenqvist, Mårten, Beyer, Thorsten, Block, Michael, den Dulk, Karel, Minten, Jaak, Lindemans, Fred·1998·Circulation

Abstract

Background —A newly developed classification system relates adverse events to the surgical procedure or the function of the implantable defibrillator. Methods and Results —Adverse events were monitored during prospective clinical evaluation of the Medtronic model 7219 Jewel ICD and were classified according to the definitions of the ISO 14155 standard for device clinical trials into 3 groups: severe and mild device-related and severe non–device-related adverse events. In addition, events were related to the surgical procedure, treatment with the device, or cardiac function. Seven hundred seventy-eight patients were followed up for an average of 4.0 months after ICD implantation. In total, 356 adverse events were observed in 259 patients. At 1, 3, and 12 months after ICD implantation, 99%, 98%, and 97% of the patients, respectively, survived; 95%, 93%, and 92%, respectively, were free of surgical reintervention; and 79%, 68%, and 51%, respectively, were free of any adverse event. Twenty patients died: 6 deaths were related to the surgical procedure, 12 deaths were considered unrelated to ICD treatment, and 2 patients died of an unknown cause. Of 111 nonlethal severe adverse device effects, 47 required surgical intervention, 19 times for correction of a dislodged lead. Inappropriate delivery of therapy was observed 128 times in 111 patients, and the events were typically resolved by reprogramming or drug adjustment. Nine of these required rehospitalization. Conclusions —Approximately 50% of patients experience an adverse event within the first year after ICD implantation. The observed adverse event rate depends on the definitions and the prospective monitoring. The incidence of inappropriate therapy emphasizes the need for improved detection algorithms and for quality-of-life evaluations, especially when considering ICD treatment in high-risk but arrhythmia-free patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.7.663

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 232

Metadata

Authors
Rosenqvist, M., Beyer, T., Block, M., den Dulk, K., Minten, J., & Lindemans, F.
Venue
Circulation
Published
1998-08-18
Volume
98
Issue
7
Pages
663-670
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2066371755
Cited by
232
References
2
FWCI
9.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adverse Events With Transvenous Implantable Cardioverter-Defibrillators: A Prospective Multicenter Study. https://app.cochat.ai/papers/10.1161/01.cir.98.7.663
The paper
Rosenqvist, M., Beyer, T., Block, M., den Dulk, K., Minten, J., & Lindemans, F. (1998). Adverse Events With Transvenous Implantable Cardioverter-Defibrillators: A Prospective Multicenter Study. Circulation. https://doi.org/10.1161/01.cir.98.7.663

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.