Jaïs, Pierre, Haïssaguerre, Michel, Shah, Dipen C., Takahashi, Atsushi, Hocini, Mélèze, Lavergne, Thomas, Lafitte, Stéphane, Le Mouroux, Alain, Fischer, Bruno, Clémenty, Jacques · 1998 · Circulation

Abstract

Background —Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. Methods and Results —Of 170 patients referred for ablation of common atrial flutter, conventional ablation of the cavotricuspid isthmus with >21 applications failed to create a bidirectional block in 13 (7.6%). An irrigated-tip catheter ablation was performed on identified gaps in the ablation line according to a protocol found to be safe in animals: a moderate flow rate of 17 mL/min and temperature-controlled (target, 50°C) RF delivery with a power limit of 50 W. Bidirectional isthmus block was achieved in 12 patients by use of a mean delivered power of 40±6 W with a single application in 6 patients and 2 to 6 applications in the other 6. No side effects occurred during or after the procedure. Conclusions —Irrigated-tip catheter ablation is safe and effective for achieving cavotricuspid isthmus block when conventional RF energy has failed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.98.9.835

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Jaïs, P., Haïssaguerre, M., Shah, D. C., Takahashi, A., Hocini, M., Lavergne, T., Lafitte, S., Le Mouroux, A., Fischer, B., & Clémenty, J.
Venue
Circulation
Published
1998-09
Volume
98
Issue
9
Pages
835-838
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2081381756
Cited by
169
References
0
FWCI
7.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Successful Irrigated-Tip Catheter Ablation of Atrial Flutter Resistant to Conventional Radiofrequency Ablation. https://app.cochat.ai/papers/10.1161/01.cir.98.9.835
The paper
Jaïs, P., Haïssaguerre, M., Shah, D. C., Takahashi, A., Hocini, M., Lavergne, T., Lafitte, S., Le Mouroux, A., Fischer, B., & Clémenty, J. (1998). Successful Irrigated-Tip Catheter Ablation of Atrial Flutter Resistant to Conventional Radiofrequency Ablation. Circulation. https://doi.org/10.1161/01.cir.98.9.835

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.