Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 306

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Resistant Hypertension: Comparing Hemodynamic Management to Specialist Care

Taler, Sandra J., Textor, Stephen C., Augustine, Jo Ellen · 2002 · Hypertension

Abstract

Although resistant hypertension affects a minority of all hypertensives, this group continues to experience disproportionately high cardiovascular event rates despite newer antihypertensive agents. Hypertension represents an imbalance of hemodynamic forces within the circulation, usually characterized by elevated systemic vascular resistance. We studied the utility of serial hemodynamic parameters in the selection and titration of antihypertensive medication in resistant hypertensive patients using highly reproducible noninvasive measurements by thoracic bioimpedance. Resistant hypertension patients (n=104) were randomized to drug selection based either on serial hemodynamic (HD) measurements and a predefined algorithm or on drug selection directed by a hypertension specialist (SC) in a 3-month intensive treatment program. Blood pressure was lowered by intensified drug therapy in both treatment groups (169±3/87±2 to 139±2/72±1 mm Hg HD versus 173±3/91±2 to 147±2/79±1 mm Hg SC, P <0.01 for systolic and diastolic BP), using similar numbers and intensity of antihypertensive medications. Blood pressures were reduced further for those treated according to hemodynamic measurements, resulting in improved control rates (56% HD versus 33% SC controlled to ≤140/90 mm Hg, P <0.05) and incremental reduction in systemic vascular resistance measurements. Although the number of patients taking diuretics did not differ between groups, final diuretic dosage was higher in the hemodynamic cohort. Our results demonstrate superior blood pressure control using a treatment algorithm and serial hemodynamic measurements compared with clinical judgment alone in a randomized prospective study. Our measurements of thoracic fluid volume support occult volume expansion as a mediator of antihypertensive drug resistance and use of impedance measurements to guide advancing diuretic dose and adjustment of multidrug antihypertensive treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.0000016176.16042.2f

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 306

Metadata

Authors
Taler, S. J., Textor, S. C., & Augustine, J. E.
Venue
Hypertension
Published
2002-05
Volume
39
Issue
5
Pages
982-988
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2147924820
Cited by
306
References
30
FWCI
6.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Resistant Hypertension: Comparing Hemodynamic Management to Specialist Care. https://app.cochat.ai/papers/10.1161/01.hyp.0000016176.16042.2f
The paper
Taler, S. J., Textor, S. C., & Augustine, J. E. (2002). Resistant Hypertension: Comparing Hemodynamic Management to Specialist Care. Hypertension. https://doi.org/10.1161/01.hyp.0000016176.16042.2f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.