Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 289

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Evaluation of Carotid-Femoral Pulse Wave Velocity: Influence of Timing Algorithm and Heart Rate

Millasseau, Sandrine C., Stewart, Andrew D., Patel, Sundip J., Redwood, Simon R., Chowienczyk, Philip J. · 2005 · Hypertension

Abstract

Carotid-femoral pulse wave velocity (PWV), a measure of arterial stiffness, is determined from the time taken for the arterial pulse to propagate from the carotid to the femoral artery. Propagation time is measured variously from the foot of the waveform or point of maximum upslope. We investigated whether these methods give comparable values of PWV at rest, during β-adrenergic stimulation, and pacing-induced tachycardia. In subjects at rest (n=43), values obtained using the foot-to-foot method (SphygmoCor system) were 1.7±0.75 m/s (mean±SD) greater than those obtained using the maximum slope (Complior system) at a mean value of 12 m/s. Isoprotenerol (0.5 to 1.5 μg/min; n=10), and pacing (in subjects with permanent pacemakers; n=11) increased heart rate but had differential effects on systolic blood pressure and pulse pressure. The increase in heart rate produced by isoprotenerol (18±3 bpm) and pacing (40 bpm) was associated with an increase in PWV measured using both systems (increases of 0.7±0.2 m/s and 0.9±0.2 m/s for SphygmoCor and Complior, respectively, during isoprotenerol and increases of 2.1±0.5 m/s and 1.1±0.2 m/s for SphygmoCor and Complior, respectively, during pacing, each P <0.001). Reanalysis of waveforms recorded from the Complior system using the foot-to-foot method produced similar values of PWV to those obtained with the SphygmoCor, confirming that the difference between these systems was attributable to the timing algorithm rather than other aspects of signal acquisition. Carotid-femoral PWV is critically dependent on the method used to determine propagation time, but this does not account for variation of PWV with heart rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.0000154229.97341.d2

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 289

Metadata

Authors
Millasseau, S. C., Stewart, A. D., Patel, S. J., Redwood, S. R., & Chowienczyk, P. J.
Venue
Hypertension
Published
2005-02
Volume
45
Issue
2
Pages
222-226
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2170283410
Cited by
289
References
25
FWCI
4.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Carotid-Femoral Pulse Wave Velocity: Influence of Timing Algorithm and Heart Rate. https://app.cochat.ai/papers/10.1161/01.hyp.0000154229.97341.d2
The paper
Millasseau, S. C., Stewart, A. D., Patel, S. J., Redwood, S. R., & Chowienczyk, P. J. (2005). Evaluation of Carotid-Femoral Pulse Wave Velocity: Influence of Timing Algorithm and Heart Rate. Hypertension. https://doi.org/10.1161/01.hyp.0000154229.97341.d2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.