Arterial vascular compliance response to vasodilators by Fourier and pulse contour analysis.
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Vasodilator drugs are widely used in the management of cardiovascular disease. They decrease systemic vascular resistance, but they also may influence vascular arterial compliance. This study evaluated the effects of three vasodilators--nitroprusside, nitroglycerin, and hydralazine--on vascular compliance using impedance parameters determined by pulse contour and Fourier analyses. The open chest study was performed on anesthetized dogs. Mean arterial pressure decreased by a minimum of 20% after vasodilator intervention. The decrease in systemic vascular resistance was significant (p less than 0.01) only after hydralazine treatment. Proximal compliance increased after administration of all drugs, but the increase was not statistically significant. Distal compliance determined by pulse contour analysis increased by 60 to 120% after all three drug treatments (p less than 0.05 for nitroprusside, p less than 0.02 for nitroglycerin and hydralazine). Characteristic impedance from Fourier analysis responded variably, and changes were not statistically significant. The sensitivity of changes in distal compliance as a marker for the vascular effect of these drugs suggests that it might be used as a more reliable guide than blood pressure or vascular resistance in monitoring clinical response to such intervention. The more traditional measure of characteristic impedance provides a vascular measurement that is less sensitive than distal compliance to the effects of these vasodilator drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Vasodilator Therapy on Mortality in Chronic Congestive Heart Failure
Cohn, J. N., Archibald, D. G., Ziesche, S., Franciosa, J. A., Harston, W. E., Tristani, F. E., Dunkman, W. B., Jacobs, W., Francis, G. S., Flohr, K. H., et al. (1986) · New England Journal of Medicine · doi:10.1056/nejm198606123142404 · Cited by 2,400
Self-citation
Cited by
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Vascular Compliance and Cardiovascular Disease A Risk Factor or a Marker?
Glasser, S. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00311-7 · Cited by 308
Color Doppler Analysis of Ocular Vessel Blood Velocity in Normal-tension Glaucoma
Harris, A., Sergott, R. C., Spaeth, G. L., Katz, J. L., Shoemaker, J. A., & Martin, B. J. (1994) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)76579-1 · Cited by 298
Tardy, Y., Meister, J. J., Perret, F., Brunner, H. R., & Arditi, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/1/003 · Cited by 270
Metadata
- Authors
- Finkelstein, S. M., Collins, V. R., & Cohn, J. N.
- Venue
- Hypertension
- Published
- 1988-10
- Volume
- 12
- Issue
- 4
- Pages
- 380-387
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2048419372
- Cited by
- 85
- References
- 1
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.