Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record.

Determinants of angiotensin II generation during converting enzyme inhibition.

Open access
Juillerat, L, Nussberger, J, Ménard, J, Mooser, V, Christen, Y, Waeber, B, Graf, P, Brunner, H R·1990·Hypertension

Abstract

The reaction of the renin-angiotensin system to acute angiotensin converting enzyme inhibition was investigated in a single-blind, crossover study in nine normal volunteers receiving two out of three regimens in random order: the new converting enzyme inhibitor benazepril (20 mg once or 5 mg four times at 6-hour intervals) or enalapril (20 mg). Plasma converting enzyme activity, drug levels, angiotensin I and angiotensin II, active renin, and aldosterone were measured before and 1-4 hours and 14-30 hours after drug intake. Baseline in vitro plasma converting enzyme activity was 97 +/- 15 nmol/ml/min (mean +/- SD) when Hip-Gly-Gly was used as substrate, but with carbobenzoxy-Phe-His-Leu (Z-Phe-His-Leu) or angiotensin I as substrate it was only 20 +/- 4 and 1.7 +/- 0.3 nmol/ml/min, respectively. Discriminating power at peak converting enzyme inhibition was enhanced with the two latter substrates. In vivo converting enzyme activity was estimated by the plasma angiotensin II/angiotensin I ratio, which correlated well with in vitro converting enzyme activity using Z-Phe-His-Leu as substrate (r = 0.76, n = 252). Angiotensin II levels returned to baseline less than 24 hours after drug administration, whereas in vitro and in vivo converting enzyme activity remained considerably inhibited and active renin together with angiotensin I levels were still elevated. A close linear relation was found between plasma angiotensin II and the angiotensin I/drug level ratio (r = 0.91 for benazeprilat and r = 0.88 for enalaprilat, p less than 0.001). Thus, plasma angiotensin II truly reflects the resetting of the renin-angiotensin system at any degree of converting enzyme inhibition. The ratio of plasma angiotensin II to angiotensin I represents converting enzyme inhibition more accurately than in vitro assays, which vary considerably depending on substrates and assay conditions used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.16.5.564

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
Juillerat, L., Nussberger, J., Ménard, J., Mooser, V, Christen, Y., Waeber, B., Graf, P., & Brunner, H. R.
Venue
Hypertension
Published
1990-11
Volume
16
Issue
5
Pages
564-572
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2138806344
Cited by
212
References
0
FWCI
5.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determinants of angiotensin II generation during converting enzyme inhibition. https://app.cochat.ai/papers/10.1161/01.hyp.16.5.564
The paper
Juillerat, L., Nussberger, J., Ménard, J., Mooser, V, Christen, Y., Waeber, B., Graf, P., & Brunner, H. R. (1990). Determinants of angiotensin II generation during converting enzyme inhibition. Hypertension. https://doi.org/10.1161/01.hyp.16.5.564

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.