The DOI matches its Crossref record.
Differential regulation of angiotensin peptide levels in plasma and kidney of the rat.
Open accessAbstract
We compared the effects of the converting enzyme inhibitor perindopril on components of the renin-angiotensin system in plasma and kidney of male Sprague-Dawley rats administered perindopril in their drinking water at two doses (1.4 and 4.2 mg/kg) over 7 days. Eight angiotensin peptides were measured in plasma and kidney: angiotensin-(1-7), angiotensin II, angiotensin-(1-9), angiotensin I, angiotensin-(2-7), angiotensin III, angiotensin-(2-9), and angiotensin-(2-10). In addition, angiotensin converting enzyme activity, renin, and angiotensinogen were measured in plasma, and renin, angiotensinogen, and their respective messenger RNAs were measured in kidney; angiotensinogen messenger RNA was also measured in liver. In plasma, the highest dose of perindopril reduced angiotensin converting enzyme activity to 11% of control, increased renin 200-fold, reduced angiotensinogen to 11% of control, increased angiotensin-(1-7), angiotensin I, angiotensin-(2-7), and angiotensin-(2-10) levels 25-, 9-, 10-, and 13-fold, respectively; angiotensin II levels were not significantly different from control. By contrast, for the kidney, angiotensin-(1-7), angiotensin I, angiotensin-(2-7), and angiotensin-(2-10) levels did not increase; angiotensin II levels fell to 14% of control, and angiotensinogen fell to 12% of control. Kidney renin messenger RNA levels increased 12-fold, but renal renin content and angiotensinogen messenger RNA levels in kidney and liver were not influenced by perindopril treatment. These results demonstrate a differential regulation of angiotensin peptides in plasma and kidney and provide direct support for the proposal that the cardiovascular effects of converting enzyme inhibitors depend on modulation of tissue angiotensin systems. Moreover, the failure of kidney angiotensin I levels to increase with perindopril treatment, taken together with the fall in kidney angiotensinogen levels, suggests that angiotensinogen may be a major rate-limiting determinant of angiotensin peptide levels in the kidney.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Li, X. C., Zhang, J., & Zhuo, J. L. (2017) · Pharmacological Research · doi:10.1016/j.phrs.2017.06.005 · Cited by 435
Regulation of Intrarenal Angiotensin II in Hypertension
Navar, L. G., Harrison-Bernard, L. M., Nishiyama, A., & Kobori, H. (2002) · Hypertension · doi:10.1161/hy0202.103821 · Cited by 375
Effects of converting enzyme inhibitors on angiotensin and bradykinin peptides.
Campbell, D. J., Kladis, A., & Duncan, A. M. (1994) · Hypertension · doi:10.1161/01.hyp.23.4.439 · Cited by 317
Self-citationTonellotto dos Santos, J., Ferreira, R., Gasperin, B. G., Siqueira, L. C., de Oliveira, J. F., Santos, R. A., Reis, A. M., & Gonçalves, P. B. (2012) · Journal of the Renin-Angiotensin-Aldosterone System · doi:10.1177/1470320311417273 · Cited by 57
Barreta, M. H., Gasperin, B. G., Ferreira, R., Rovani, M., Pereira, G. R., Bohrer, R. C., de Oliveira, J. F., & Gonçalves, P. B. D. (2015) · Journal of the Renin-Angiotensin-Aldosterone System · doi:10.1177/1470320313491996 · Cited by 34
Metadata
- Authors
- Campbell, D. J., Lawrence, A. C., Towrie, A., Kladis, A., & Valentijn, A. J.
- Venue
- Hypertension
- Published
- 1991-12
- Volume
- 18
- Issue
- 6
- Pages
- 763-773
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W1975291885
- Cited by
- 242
- References
- 0
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differential regulation of angiotensin peptide levels in plasma and kidney of the rat. https://app.cochat.ai/papers/10.1161/01.hyp.18.6.763
- The paper
- Campbell, D. J., Lawrence, A. C., Towrie, A., Kladis, A., & Valentijn, A. J. (1991). Differential regulation of angiotensin peptide levels in plasma and kidney of the rat. Hypertension. https://doi.org/10.1161/01.hyp.18.6.763
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.