Determinants of Pulse Pressure
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstract —We have searched to define the major arterial parameters that determine aortic systolic (P s ) and diastolic (P d ) pressure in the dog. Measured aortic flows were used as input to the 2-element windkessel model of the arterial system, with peripheral resistance calculated as mean pressure divided by mean flow and total arterial compliance calculated from the decay time in diastole. The windkessel model yielded an aortic pressure wave from which we obtained the predicted systolic (P s,wk ) and diastolic (P d,wk ) pressures. These predicted pressures were compared with the measured systolic and diastolic pressures. The measurements and calculations were performed for 7 dogs under control conditions during aortic occlusion at 4 locations (the trifurcation, between the trifurcation and diaphragm, the diaphragm, and the proximal descending thoracic aorta) and during occlusion of both carotid arteries. Under all conditions studied, the predicted systolic and diastolic pressures matched the experimental ones very well: P s,wk =(1.000±0.0055) P s with r =0.958 and P d,wk =(1.024±0.0035) P d with r =0.995. Linear regression for pulse pressure (PP) resulted in PP wk =(0.99±0.016) PP with r =0.911. We found the accuracy of prediction equally good under control conditions and in the presence of aortic or carotid artery occlusion. Multiple regression between pulse pressure and arterial resistance and total arterial compliance yielded a poor regression constant ( R 2 =0.19), suggesting that the 2 arterial parameters alone cannot explain pulse pressure and that flow is an important determinant as well. We conclude that for a given ejection pattern (aortic flow), 2 arterial parameters, total arterial resistance and total arterial compliance, are sufficient to accurately describe systolic and diastolic aortic pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
MILLASSEAU, S. C., KELLY, R. P., RITTER, J. M., & CHOWIENCZYK, P. J. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 613
Wang, K.-L., Cheng, H.-M., Chuang, S.-Y., Spurgeon, H. A., Ting, C.-T., Lakatta, E. G., Yin, F. C., Chou, P., & Chen, C.-H. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283220ea4 · Cited by 362
Wave propagation in a model of the arterial circulation
Wang, J. J., & Parker, K. H. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.007 · Cited by 270
Clinical achievements of impedance analysis
Mitchell, G. F. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0402-3 · Cited by 63
Dong, Y., Jiang, L., Wang, X., Chen, Z., Zhang, L., Zhang, Z., Zheng, C., Kang, Y., Wang, Z., Cao, H., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.13838 · Cited by 22
Metadata
- Authors
- Stergiopulos, N., & Westerhof, N.
- Venue
- Hypertension
- Published
- 1998-09
- Volume
- 32
- Issue
- 3
- Pages
- 556-559
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2118739707
- Cited by
- 78
- References
- 1
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.