Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 208

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Angiotensin-(1-7)–Stimulated Nitric Oxide and Superoxide Release From Endothelial Cells

Heitsch, Holger, Brovkovych, Svitlana, Malinski, Tadeusz, Wiemer, Gabriele · 2001 · Hypertension

Abstract

Abstract—The stimulation of endothelium-dependent NO release by angiotensin-(1-7) [Ang-(1-7)] has been indirectly shown in terms of vasodilation, which was diminished by NO synthase inhibition or removal of the endothelium. However, direct measurement of endothelium-derived NO has not been analyzed. With a selective porphyrinic microsensor, NO release was directly assessed from single primary cultured bovine aortic endothelial cells. Ang-(1-7) caused a concentration-dependent release of NO of 1 to 10 μmol/L, which was attenuated by NO synthase inhibition. [d-Ala 7]Ang-(1-7) (5 μmol/L), described as a selective antagonist of Ang-(1-7) receptors, inhibited Ang-(1-7)–induced NO release only by ≈50%, whereas preincubation of bovine aortic endothelial cells with the angiotensin II subtype 1 and 2 receptor antagonists EXP 3174 and PD 123,177 (both at 0.1 μmol/L) led to an inhibition of 60% and 90%, respectively. A complete blockade of the Ang-(1-7)–induced NO release was observed on preincubation of the cells with 1 μmol/L concentration of the bradykinin subtype 2 receptor antagonist icatibant (HOE 140), suggesting an important role of local kinins in the action of Ang-(1-7). Simultaneous direct measurement of superoxide (O 2−) detected by an O 2−-sensitive microsensor revealed that the moderately Ang-(1-7)–stimulated NO release was accompanied by a very slow concomitant O 2−production with a relative low peak concentration in comparison to the O 2−production of the strong NO releasers bradykinin and, especially, calcium ionophore. Thus, Ang-(1-7) might preserve the vascular system, among others, due to its low formation of cytotoxic peroxynitrite by the reaction between NO and O 2−.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.hyp.37.1.72

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 208

Metadata

Authors
Heitsch, H., Brovkovych, S., Malinski, T., & Wiemer, G.
Venue
Hypertension
Published
2001-01
Volume
37
Issue
1
Pages
72-76
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2147748270
Cited by
208
References
1
FWCI
5.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.