Reproducibility of echocardiographic left ventricular measurements.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Serial echocardiograms with acceptable reproducibility of measurements may be produced by careful performance and interpretation of the studies. The following recommendations have been shown to enhance reproducibility. Strict adherence to quality control is necessary to generate echocardiograms of the highest technical quality. Sonographers should be aware of the definition of a technically adequate study--including correct beam or plane angulation and continuous visualization of interfaces--and seek this ideal in every study. Participation by the sonographer in performance of measurements enhances recognition of the requirements for accurate quantitative echocardiography. Regular machine calibration is a prerequisite to accurate quantitative echocardiography. Considerable effort must be made to standardize the position of each acoustic window and angulation from which the patient is imaged--with deviation from these norms being recorded for future reference. If at all possible, measurements should be taken at end expiration. If that is not possible, measurement of several consecutive beats will limit the impact of respiratory variation. A uniform convention of measurement should be adopted. The best candidates for M-mode measurements are the American Society of Echocardiography recommendations for general measurement and the Penn convention for calculation of M-mode left ventricular mass. Further data is needed to determine which approaches to two-dimensional measurements best combine accuracy and reproducibility. Interpretation of echocardiograms may be made most reproducible by measuring pertinent parameters from multiple beats and using the mean as the result and by having at least two readers interpret each echocardiogram, possibly with two separate readings by each reader.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparative left ventricular dimensions in trained athletes
MORGANROTH, J., MARON, B. J., HENRY, W. L., & EPSTEIN, S. E. (1975) · Annals of Internal Medicine · doi:10.7326/0003-4819-82-4-521 · Cited by 866
Cited by
de Simone, G., Daniels, S. R., Devereux, R. B., Meyer, R. A., Roman, M. J., de Divitiis, O., & Alderman, M. H. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90385-z · Cited by 1,734
Self-citationBrush, J. E., Cannon, R. O., Schenke, W. H., Bonow, R. O., Leon, M. B., Maron, B. J., & Epstein, S. E. (1988) · New England Journal of Medicine · doi:10.1056/nejm198811173192002 · Cited by 435
Schwartzkopff, B., Motz, W., Frenzel, H., Vogt, M., Knauer, S., & Strauer, B. E. (1993) · Circulation · doi:10.1161/01.cir.88.3.993 · Cited by 385
de Simone, G., Devereux, R. B., Koren, M. J., Mensah, G. A., Casale, P. N., & Laragh, J. H. (1996) · Circulation · doi:10.1161/01.cir.93.2.259 · Cited by 374
Self-citationBOTTINI, P., CARR, A., PRISANT, L., FLICKINGER, F., ALLISON, J., & GOTTDIENER, J. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(94)00178-e · Cited by 363
Metadata
- Authors
- Wallerson, D. C., & Devereux, R. B.
- Venue
- Hypertension
- Published
- 1987-02
- Volume
- 9
- Issue
- 2_pt_2
- Pages
- II6-18
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W1964207410
- Cited by
- 135
- References
- 1
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.