CoChat

Electrical Propagation in Synthetic Ventricular Myocyte Strands From Germline Connexin43 Knockout Mice

Beauchamp, Philippe, Choby, Cécile, Desplantez, Thomas, de Peyer, Karin, Green, Karen, Yamada, Kathryn A., Weingart, Robert, Saffitz, Jeffrey E., Kléber, André G. · 2004 · Circulation Research
Cited by 115

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

To characterize the role of connexin43 (Cx43) as a determinant of cardiac propagation, we synthesized strands and pairs of ventricular myocytes from germline Cx43 −/− mice. The amount of Cx43, Cx45, and Cx40 in gap junctions was analyzed by immunohistochemistry and confocal microscopy. Intercellular electrical conductance, g j , was measured by the dual-voltage clamp technique (DVC), and electrical propagation was assessed by multisite optical mapping of transmembrane potential using a voltage-sensitive dye. Compared with wild-type (Cx43 +/+ ) strands, immunoreactive signal for Cx43 was reduced by 46% in Cx43 +/− strands and was absent in Cx43 −/− strands. Cx45 signal was reduced by 46% in Cx43 +/− strands and to the limit of detection in Cx43 −/− strands, but total Cx45 protein levels measured in immunoblots of whole cell homogenates were equivalent in all genotypes. Cx40 was detected in ≈ 2% of myocytes. Intercellular conductance, g j , was reduced by 32% in Cx43 +/− cell pairs and by 96% in Cx43 −/− cell pairs. The symmetrical dependence of g j on transjunctional voltage and properties of single-channel recordings indicated that Cx45 was the only remaining connexin in Cx43 −/− cells. Propagation in Cx43 −/− strands was very slow (2.1 cm/s versus 52 cm/s in Cx43 +/+ ) and highly discontinuous, with simultaneous excitation within and long conduction delays (2 to 3 ms) between individual cells. Propagation was abolished by 1 mmol/L heptanol, indicating residual junctional coupling. In summary, knockout of Cx43 in ventricular myocytes leads to very slow conduction dependent on the presence of Cx45. Electrical field effect transmission does not contribute to propagation in synthetic strands.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.0000134923.05174.2f

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 115

Metadata

Authors
Beauchamp, P., Choby, C., Desplantez, T., de Peyer, K., Green, K., Yamada, K. A., Weingart, R., Saffitz, J. E., & Kléber, A. G.
Venue
Circulation Research
Published
2004-07-23
Volume
95
Issue
2
Pages
170-178
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2056018872
Cited by
115
References
1
FWCI
2.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical Propagation in Synthetic Ventricular Myocyte Strands From Germline Connexin43 Knockout Mice. https://app.cochat.ai/papers/10.1161/01.res.0000134923.05174.2f
The paper
Beauchamp, P., Choby, C., Desplantez, T., de Peyer, K., Green, K., Yamada, K. A., Weingart, R., Saffitz, J. E., & Kléber, A. G. (2004). Electrical Propagation in Synthetic Ventricular Myocyte Strands From Germline Connexin43 Knockout Mice. Circulation Research. https://doi.org/10.1161/01.res.0000134923.05174.2f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.