The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Resistivity of Body Tissues at Low Frequencies
Open accessAbstract
The resistivity of tissues of the thorax of dogs has been measured in situ under nearly normal conditions. Additional data have been obtained from humans. Approximate values of tissue resistivity found are 160 ohm-cm for blood, 2,000 ohm-cm for lung, 2,500 ohm-cm for fat, 700 ohm-cm for liver, 250 and 550 ohm-cm (anisotropic) for heart muscle and 150 and 2,500 ohm-cm (anisotropic) for skeletal muscle. Reasons for the differences between these and previously reported values have been found, and in some cases, verified experimentally. Predictions of whole trunk resistivity based on anatomical data and these measurements are within 8% of actual trunk measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An orthogonal lead system for clinical electrocardiography
McFee, R., & Parungao, A. (1961) · American Heart Journal · doi:10.1016/0002-8703(61)90488-4 · Cited by 241
Self-citationTHE CONDUCTIVITY OF LIVING TISSUES
Schwan, H. P., & Kay, C. F. (1957) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1957.tb36701.x · Cited by 238
Specific Resistance of Body Tissues
SCHWAN, H. P., & KAY, C. F. (1956) · Circulation Research · doi:10.1161/01.res.4.6.664 · Cited by 187
Eycleshymer, A. C., & Schoemaker, D. M. (1970) · Medical Entomology and Zoology · Cited by 185
Specific Electric Resistance of Body Tissues
Bürger, H., & van Dongen, R. (1961) · Physics in Medicine and Biology · doi:10.1088/0031-9155/5/4/304 · Cited by 125
Measurements of the specific Resistance of the human Body to direct Current
Bürger, H., & Milaan, J. B. V. (1943) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1943.tb11253.x · Cited by 123
Cited by
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Barber, D. C., & Brown, B. H. (1984) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/17/9/002 · Cited by 726
Electrical conductivity of tissue at frequencies below 1 MHz
Gabriel, C., Peyman, A., & Grant, E. H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/16/002 · Cited by 716
Considerations of quasi-stationarity in electrophysiological systems
Plonsey, R., & Heppner, D. B. (1967) · The Bulletin of Mathematical Biophysics · doi:10.1007/bf02476917 · Cited by 619
Roberts, D. E., Hersh, L. T., & Scher, A. M. (1979) · Circulation Research · doi:10.1161/01.res.44.5.701 · Cited by 437
Metadata
- Authors
- RUSH, S., ABILDSKOV, J. A., & MCFEE, R.
- Venue
- Circulation Research
- Published
- 1963-01
- Volume
- 12
- Issue
- 1
- Pages
- 40-50
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1996034597
- Cited by
- 447
- References
- 6
- FWCI
- 6.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.