The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Dimensions of Blood Vessels from Distributing Artery to Collecting Vein
Open accessAbstract
Measurements of lengths, diameters, and numbers of post-capillary vessels were made in the bat's wing. The cross-sectional area and capacity in the various portions of the vascular bed were calculated. The greatest total cross-sectional area in the entire vascular bed was found in the venules, a result not in agreement with similar reports made by others using measurements from vessels in fixed preparations. This discrepancy probably results from disagreement regarding the diameter of capillary vessels. Calculations to determine the per cent of total volume in each portion of the vascular bed showed that the venous system accounts for as much as 80% of the total vascular volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Anatomy and Physiology of Capillaries.
(1929) · Journal of the American Medical Association · doi:10.1001/jama.1929.02710200070040 · Cited by 859
Lengths and Diameters of Peripheral Arterial Vessels in the Living Animal
WIEDEMAN, M. P. (1962) · Circulation Research · doi:10.1161/01.res.10.4.686 · Cited by 38
Self-citation
Cited by
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Crossing kingdoms: Using decellularized plants as perfusable tissue engineering scaffolds
Gershlak, J. R., Hernandez, S., Fontana, G., Perreault, L. R., Hansen, K. J., Larson, S. A., Binder, B. Y. K., Dolivo, D. M., Yang, T., Dominko, T., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.02.011 · Cited by 375
Astrocytic laminin regulates pericyte differentiation and maintains blood brain barrier integrity
Yao, Y., Chen, Z.-L., Norris, E. H., & Strickland, S. (2014) · Nature Communications · doi:10.1038/ncomms4413 · Cited by 357
MORPHOMETRIC DATA ON THE ENDOTHELIUM OF BLOOD CAPILLARIES
Simionescu, M., Simionescu, N., & Palade, G. E. (1974) · The Journal of Cell Biology · doi:10.1083/jcb.60.1.128 · Cited by 294
Keller, M. W., Segal, S. S., Kaul, S., & Duling, B. (1989) · Circulation Research · doi:10.1161/01.res.65.2.458 · Cited by 267
Metadata
- Authors
- WIEDEMAN, M. P.
- Venue
- Circulation Research
- Published
- 1963-04
- Volume
- 12
- Issue
- 4
- Pages
- 375-378
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2095499837
- Cited by
- 288
- References
- 2
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dimensions of Blood Vessels from Distributing Artery to Collecting Vein. https://app.cochat.ai/papers/10.1161/01.res.12.4.375
- The paper
- WIEDEMAN, M. P. (1963). Dimensions of Blood Vessels from Distributing Artery to Collecting Vein. Circulation Research. https://doi.org/10.1161/01.res.12.4.375
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.