Dispersion and Attenuation of Small Artificial Pressure Waves in the Canine Aorta
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A method was developed to determine the elastic behavior of large blood vessels in terms of their transmission characteristics for small sinusoidal pressure signals. The method is new insofar as it utilizes transient signals of the form of finite trains of sine waves that are superimposed on the naturally occurring pressure fluctuations and are generated by an electrically driven impactor or by a pump. Its application to the thoracic aortas of 18 mature mongrel dogs anesthetized with pentobarbital has shown that dispersion and attenuation data for frequencies between 40 and 200 cps can be obtained without requiring either Fourier transform computations or resolution of reflection interference. For the frequency range considered, the descending aorta is only mildly dispersive but exhibits strong attenuation that must be attributed primarily to dissipative mechanisms in the vessel wall. At normal blood pressure levels, the wave speed during diastole can have a value between 4 and 6 m/sec. For all frequencies tested the amplitude ratio of the waves exhibits the same exponential decay pattern with distance measured in wavelengths. A marked increase in wave speed observed from diastole to systole can be associated with an increase in mean flow and with a stiffening of the aortic wall due to the rise in pressure. This phenomenon implies that the aortas of anesthetized dogs should exhibit nonlinear properties with respect to large amplitude pulse waves such as those generated by the heart.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wave Propagation in a Viscous Liquid Contained in a Flexible Tube
Morgan, G. W., & Kiely, J. P. (1954) · The Journal of the Acoustical Society of America · doi:10.1121/1.1907335 · Cited by 156
Cited by
Determination of pulse wave velocities with computerized algorithms
Chiu, Y. C., Arand, P. W., Shroff, S. G., Feldman, T., & Carroll, J. D. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90153-9 · Cited by 313
Anliker, M., Rockwell, R. L., & Ogden, E. (1971) · Zeitschrift für angewandte Mathematik und Physik ZAMP · doi:10.1007/bf01591407 · Cited by 202
Self-citationStettler, J. C., Niederer, P., & Anliker, M. (1981) · Annals of Biomedical Engineering · doi:10.1007/bf02363533 · Cited by 107
Self-citationInfluence of Flow and Pressure on Wave Propagation in the Canine Aorta
HISLAND, M. B., & ANLIKER, M. (1973) · Circulation Research · doi:10.1161/01.res.32.4.524 · Cited by 48
Self-citation
Metadata
- Authors
- ANLIKER, M., HISTAND, M. B., & OGDEN, E.
- Venue
- Circulation Research
- Published
- 1968-10
- Volume
- 23
- Issue
- 4
- Pages
- 539-551
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1972254609
- Cited by
- 141
- References
- 1
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dispersion and Attenuation of Small Artificial Pressure Waves in the Canine Aorta. https://app.cochat.ai/papers/10.1161/01.res.23.4.539
- The paper
- ANLIKER, M., HISTAND, M. B., & OGDEN, E. (1968). Dispersion and Attenuation of Small Artificial Pressure Waves in the Canine Aorta. Circulation Research. https://doi.org/10.1161/01.res.23.4.539
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.