Effect of Epinephrine on Pressure, Flow, and Volume Relationships in the Systemic Circulation of Dogs
Open accessThe DOI matches its Crossref record.
Abstract
The effect of epinephrine on peripheral circulation was studied in ten anesthetized open-chest dogs. Blood flow and right atrial pressure were independently controlled by a right heart bypass; changes in blood volume could be precisely determined from the changes occurring in the bypass reservoir. At constant blood flow and right atrial pressure, a constant infusion of epinephrine (5.8 µg/kg min -1 ) decreased blood volume by an average of 208 ml. During epinephrine infusion, the ratio of changes in blood volume to changes in blood flow measured at constant right atrial pressure, (Δ V /Δ Q · ) Pra , decreased from 0.226 minutes to 0.153 minutes and the ratio of changes in blood volume to changes in right atrial pressure at constant blood flow, the vascular compliance, decreased from 27.1 ml/cm H 2 O to 20.7 ml/cm H 2 O. Transient changes in blood volume following a step decrease in right atrial pressure at constant blood flow showed that blood was draining from two vascular compartments with different time constants: 0.059 minutes and 0.388 minutes before epinephrine infusion and 0.058 minutes and 0.486 minutes during epinephrine infusion. We analyzed the data using a mathematical model of the peripheral circulation consisting of two compartments with different time constants. The analysis showed that the primary effect of epinephrine on the systemic circulation was to redistribute blood flow away from the compartment with the longest time constant. The reduction in (ΔV/Δ Q · ) pra and the decrease in blood volume at constant flow and right atrial pressure were essentially determined by the change in flow distribution brought about by a change in arteriolar tone and not by a change in venous tone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Pathophysiology of Aortic Cross-clamping and Unclamping
Gelman, S. (1995) · Anesthesiology · doi:10.1097/00000542-199504000-00027 · Cited by 603
Venous Function and Central Venous Pressure: A Physiologic Story
Gelman, S., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181672607 · Cited by 575
Alterations in vasomotor tone in congestive heart failure
Zelis, R., & Flaim, S. F. (1982) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(82)90012-3 · Cited by 363
Cardiovascular Adjustments to Gravitational Stress
Blomqvist, C. G., & Stone, H. L. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020328 · Cited by 291
Integration of Cardiovascular Control Systems in Dynamic Exercise
Rowell, L. B., O'Leary, D. S., & Kellogg, D. L. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp120117 · Cited by 217
Venous System: Physiology of the Capacitance Vessels
Rothe, C. F. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020313 · Cited by 197
Cardiovascular Adjustments to Thermal Stress
Rowell, L. B. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020327 · Cited by 195
Baroreflex Control of Systemic Arterial Pressure and Vascular Bed
Sagawa, K. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020314 · Cited by 182
Averina, V. A., Othmer, H. G., Fink, G. D., & Osborn, J. W. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.228619 · Cited by 41
“Values of the model parameters (Table 2) and initial values of the model variables (Table 3) have been taken from the physiological and modelling literature (Caldini et al. 1974; Guyton, 1980; Ursino, 1998; Karaaslan et al. 2005).”
Method
Metadata
- Authors
- CALDINI, P., PERMUTT, S., WADDELL, J. A., & RILEY, R. L.
- Venue
- Circulation Research
- Published
- 1974-05
- Volume
- 34
- Issue
- 5
- Pages
- 606-623
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2172148175
- Cited by
- 196
- References
- 0
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.