The DOI matches its Crossref record.
Alterations in canine myocardial excitability during ischemia.
Open accessAbstract
Changes in the ventricular diastolic excitability threshold following occlusion of the left anterior descending coronary artery (LAD) were studied in open-chest anesthetized dogs by using a new automatic threshold-following pacemaker (ATFP). The ATFP measures the diastolic excitability threshold by successively decreasing the duration of regularly occurring pacing stimuli until the ventricle fails to respond. Under control conditions, the threshold stimulus duration was 60 +/- 4 (mean +/- SEM) musec. In the first 1-3 minutes following occlusion of the LAD, the diastolic excitability threshold in the ischemic zone (IZ) decreased to 51 +/- 5 musec and then rapidly increased to 600 musec at 5 minutes. The initial decrease in excitability threshold at IZ could be abolished by elevating the serum K+ concentration prior to the LAD occlusion. These changes in excitability threshold at IZ could be prevented by infusing nonoxygenated solutions into the LAD at a site distal to the occlusion. As the excitability threshold increased in IZ during ischemia, the earliest time at which IZ could be reactivated by a stimulus with a voltage equal to twice the preligation diastolic voltage threshold was increased. In nine of 16 dogs, after 5 minutes of LAD ligation, the IZ to normal zone (NZ( activation time (when stimulating at IZ) exceeded the NZ to IZ activation time (when stimulating at NZ) by an average of 9 msec. We also found that in four dogs the NZ to IZ activation time exceeded the IZ to NZ activation time by an average of 10 msec. We conclude from these findings that a gradient of increasing excitability threshold exists as one moves from normally perfused toward more ischemic tissue, passing through a heterogenous border zone that manifests some areas which have a decreased excitability threshold and other areas which have an increased excitability threshold, and that these changes in excitability importantly influence the determination of refractory period durations and conduction times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood pressure, stroke, and coronary heart disease
Collins, R., Peto, R., MacMahon, S., Godwin, J., Qizilbash, N., Collins, R., MacMahon, S., Hebert, P., Eberlein, K. A., Taylor, J. O., et al. (1990) · The Lancet · doi:10.1016/0140-6736(90)90944-z · Cited by 4,491
Webb, A. J., Fischer, U., Mehta, Z., & Rothwell, P. M. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60235-8 · Cited by 729
Carey, R. M. (1984) · Archives of Internal Medicine · doi:10.1001/archinte.1984.00350170211032 · Cited by 593
Thomopoulos, C., Parati, G., & Zanchetti, A. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000378 · Cited by 388
Thomopoulos, C., Parati, G., & Zanchetti, A. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000000881 · Cited by 298
Metadata
- Authors
- Elharrar, V, Foster, P. R., Jirak, T. L., Gaum, W. E., & Zipes, D. P.
- Venue
- Circulation Research
- Published
- 1977-01
- Volume
- 40
- Issue
- 1
- Pages
- 98-105
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1985693949
- Cited by
- 235
- References
- 0
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Alterations in canine myocardial excitability during ischemia. https://app.cochat.ai/papers/10.1161/01.res.40.1.98
- The paper
- Elharrar, V, Foster, P. R., Jirak, T. L., Gaum, W. E., & Zipes, D. P. (1977). Alterations in canine myocardial excitability during ischemia. Circulation Research. https://doi.org/10.1161/01.res.40.1.98
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.