The DOI matches its Crossref record.
The distribution of blood rheological parameters in the microvasculature of cat mesentery.
Open accessAbstract
In vivo studies of the rheological behavior of blood in the microcirculation were conducted by direct in situ measurements in cat mesentery. Upstream to downstream pressure drops were measured in unbranched arterioles, capillaries, and venules, with diameters from 7 to 58 micrometer. Simultaneous measurements of red cell velocity and vessel geometry facilitated computation of bulk velocity, pressure gradient, apparent viscosity, wall shear stress, and resistance. Arteriovenous distributions of these parameters revealed the following. Maximum pressure gradient (0.015 cm H20/micrometer) occurs in the true capillaries (7 micrometer in diameter); intravascular wall shear stress averaged 47.1 dynes/cm2 in arterioles and 29.0 dynes/cm2 in venules. Extreme values as great as 200 dynes/cm2 were observed in a few shunting arterioles. Apparent viscosity averaged 3.59 cP in arterioles, 5.15 cP in venules, and 4.22 cP overall. Intravascular resistance per unit length of microvessel varied with luminal diameter as a power law function with exponents of -4.04 for arterioles, -3.94 for venules, and -3.99 for all vessels combined. This apparent maintenance of Poiseuille's law is attributed to the opposing processes of hematocrit reduction and decreasing shear rate as blood is dispersed in successive arteriolar segments, and the converse action of these processes in the venous confluences which lessen the extent of network variations in apparent viscosity. Reductions in bulk velocity from the normal flow state to below 0.5 mm/sec resulted in increases in apparent viscosity by a factor of 2 to 10, which are attributed primarily to obstruction of the lumen by leukocyte-endothelium adhesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The History of Poiseuille's Law
Sutera, S. P., & Skalak, R. (1993) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.25.010193.000245 · Cited by 957
(2005) · PubMed · Cited by 567
Biophysical aspects of blood flow in the microvasculature
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00065-x · Cited by 553
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Self-citationIn vivo measurements of “apparent viscosity” and microvessel hematocrit in the mesentery of the cat
Lipowsky, H. H., Usami, S., & Chien, S. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90050-3 · Cited by 398
Self-citation
Metadata
- Authors
- Lipowsky, H. H., Kovalcheck, S., & Zweifach, B. W.
- Venue
- Circulation Research
- Published
- 1978-11
- Volume
- 43
- Issue
- 5
- Pages
- 738-749
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2129241682
- Cited by
- 408
- References
- 0
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The distribution of blood rheological parameters in the microvasculature of cat mesentery. https://app.cochat.ai/papers/10.1161/01.res.43.5.738
- The paper
- Lipowsky, H. H., Kovalcheck, S., & Zweifach, B. W. (1978). The distribution of blood rheological parameters in the microvasculature of cat mesentery. Circulation Research. https://doi.org/10.1161/01.res.43.5.738
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.