The DOI matches its Crossref record.
Extracellular potentials related to intracellular action potentials during impulse conduction in anisotropic canine cardiac muscle.
Abstract
This paper considers a quantitative description of intracellular and transmembrane currents in anisotropic muscle, with emphasis on the factors that determine the extracellular potentials. Although Vmax of the intracellular action potential had no relation to changes in conduction velocity in anisotropic tissue with constant membrane properties, the extracellular waveforms were quite sensitive to velocity changes. Large amplitude biphasic deflection occurred in the fast areas, and in the slow areas the waveforms were of lower amplitude and triphasic in shape; i.e., negative potentials preceded the biphasic positive-negative deflection. The extracellular potentials were simulated on the bases of a model of intracellular currents, and the theoretical and measured results showed good agreement. In tissue with anisotropic conductivity, the relationship between the spatial intracellualr potential gradient and the magnitude of the extracellular potential of the excitation wave was opposite to the classical relationship in isotropic tissue. Due to the influence of the effective intracellular conductivity on the spread of intracellular currents and on conduction velocity, in anisotropic tissue the extracellular potential decreased as the intracellular potential gradient increased. The peak values of the positive and negative potentials and the spatial distribution of the potential gradients varied considerably along the activation front. These findings were accounted for by differences in the distribution and spatial extent of the transmembrane currents, which were determined by the intracellular currents. The theoretical analysis showed that intracellular and transmembrane currents were proportional to the local conduction velocities of the wavefront. Thereby, it was not possible to have a "uniform layer" of current when there were differences in conduction velocity along the length of the excitation wave. The implications of the analysis are considerable, since the gratifying agreement between the theoretical and measured results indicates that the details of the extracellular waveforms can be explained on the basis of the distribution of intracellular currents; i.e., extracellular potentials provide a sensitive index of intracellular current flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A bidomain model for anisotropic cardiac muscle
Geselowitz, D. B., & Miller, W. T. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363286 · Cited by 273
Self-citationHigh Resolution Magnetic Images of Planar Wave Fronts Reveal Bidomain Properties of Cardiac Tissue
Holzer, J. R., Fong, L. E., Sidorov, V. Y., Wikswo, J. P., & Baudenbacher, F. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.049163 · Cited by 33
Metadata
- Authors
- Spach, M. S., Miller, W. T., Miller-Jones, E., Warren, R. B., & Barr, R. C.
- Venue
- Circulation Research
- Published
- 1979-08
- Volume
- 45
- Issue
- 2
- Pages
- 188-204
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2061533734
- Cited by
- 302
- References
- 0
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extracellular potentials related to intracellular action potentials during impulse conduction in anisotropic canine cardiac muscle. https://app.cochat.ai/papers/10.1161/01.res.45.2.188
- The paper
- Spach, M. S., Miller, W. T., Miller-Jones, E., Warren, R. B., & Barr, R. C. (1979). Extracellular potentials related to intracellular action potentials during impulse conduction in anisotropic canine cardiac muscle. Circulation Research. https://doi.org/10.1161/01.res.45.2.188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.