Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 377

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Correlation between acute reductions in myocardial blood flow and function in conscious dogs.

Vatner, S F·1980·Circulation Research

Abstract

Decreases in regional endocardial function (ultrasonic dimension technique) and blood flow (radioactive microsphere technique) were correlated in 14 conscious dogs with acute graded levels of coronary stenosis. Coronary stenosis affected overall ventricular function only slightly, but induced gradual reductions in regional blood flow (BF) and segment length (SL) shortening in the ischemic zone. The relationship was best fit by an exponential function relating % change in SL to % change in BF; i.e., SL(% delta) = -161.6 e -0.047BF(% delta) (r = 0.92). In 14 segments, where no change in function was observed, blood flow fell by 6 +/- 1%. However, 10--20% reductions of blood flow impaired function significantly. Severe reduction of blood flow was required to reduce function completely. In 12 segments exhibiting paradoxical motion, blood flow fell by 95 +/- 2%, a value greater (P < 0.01) than in four akinetic segments, i.e., those with no shortening or lengthening (-82 +/- 4%). These data, which show on one hand that only 10-20% reductions in blood flow impair function significantly and that, on the other hand, severe reductions in blood flow are required to abolish active shortening completely, indicate sensitive coupling between blood flow and function in the conscious dog with acute myocardial ischemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.47.2.201

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 377

Metadata

Authors
Vatner, S. F.
Venue
Circulation Research
Published
1980-08
Volume
47
Issue
2
Pages
201-207
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2113936179
Cited by
377
References
5
FWCI
9.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Correlation between acute reductions in myocardial blood flow and function in conscious dogs. https://app.cochat.ai/papers/10.1161/01.res.47.2.201
The paper
Vatner, S. F. (1980). Correlation between acute reductions in myocardial blood flow and function in conscious dogs. Circulation Research. https://doi.org/10.1161/01.res.47.2.201

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.