The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Correlation between acute reductions in myocardial blood flow and function in conscious dogs.
Abstract
Decreases in regional endocardial function (ultrasonic dimension technique) and blood flow (radioactive microsphere technique) were correlated in 14 conscious dogs with acute graded levels of coronary stenosis. Coronary stenosis affected overall ventricular function only slightly, but induced gradual reductions in regional blood flow (BF) and segment length (SL) shortening in the ischemic zone. The relationship was best fit by an exponential function relating % change in SL to % change in BF; i.e., SL(% delta) = -161.6 e -0.047BF(% delta) (r = 0.92). In 14 segments, where no change in function was observed, blood flow fell by 6 +/- 1%. However, 10--20% reductions of blood flow impaired function significantly. Severe reduction of blood flow was required to reduce function completely. In 12 segments exhibiting paradoxical motion, blood flow fell by 95 +/- 2%, a value greater (P < 0.01) than in four akinetic segments, i.e., those with no shortening or lengthening (-82 +/- 4%). These data, which show on one hand that only 10-20% reductions in blood flow impair function significantly and that, on the other hand, severe reductions in blood flow are required to abolish active shortening completely, indicate sensitive coupling between blood flow and function in the conscious dog with acute myocardial ischemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Methods in Medical Research
Lachenbruch, P. A. (1972) · Technometrics · doi:10.1080/00401706.1972.10488903 · Cited by 1,703
Heyndrickx, G. R., Millard, R. W., McRitchie, R. J., Maroko, P. R., & Vatner, S. F. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108178 · Cited by 1,014
Self-citationCardiovascular Control Mechanisms in the Conscious State
Vatner, S. F., & Braunwald, E. (1975) · New England Journal of Medicine · doi:10.1056/nejm197511062931906 · Cited by 390
Self-citationYasue, H., Nagao, M., Omote, S., Takizawa, A., Miwa, K., & Tanaka, S. (1978) · Circulation · doi:10.1161/01.cir.58.1.56 · Cited by 305
Waters, D. D., Luz, P. D., Wyatt, H. L., Swan, H. J. C., & Forrester, J. S. (1977) · The American Journal of Cardiology · doi:10.1016/s0002-9149(77)80163-x · Cited by 190
Cited by
Stanley, W. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00245-3 · Cited by 606
Guidelines for experimental models of myocardial ischemia and infarction
Lindsey, M. L., Bolli, R., Canty, J. M., Du, X.-J., Frangogiannis, N. G., Frantz, S., Gourdie, R. G., Holmes, J. W., Jones, S. P., Kloner, R. A., et al. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00335.2017 · Cited by 526
Metadata
- Authors
- Vatner, S. F.
- Venue
- Circulation Research
- Published
- 1980-08
- Volume
- 47
- Issue
- 2
- Pages
- 201-207
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2113936179
- Cited by
- 377
- References
- 5
- FWCI
- 9.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation between acute reductions in myocardial blood flow and function in conscious dogs. https://app.cochat.ai/papers/10.1161/01.res.47.2.201
- The paper
- Vatner, S. F. (1980). Correlation between acute reductions in myocardial blood flow and function in conscious dogs. Circulation Research. https://doi.org/10.1161/01.res.47.2.201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.