Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 374

The DOI matches its Crossref record.

Ventricular wall stress.

Open access
Yin, F C·1981·Circulation Research

Abstract

Quantification of ventricular wall stress is necessary for an understanding of both normal and pathological ventricular mechanics.At present there are no reliable means to measure, directly, wall stresses in the intact ventricle.Thus, we must rely on mathematical models to predict these stresses, knowing that the predictions cannot be validated directly.Since each model employs certain simplifying assumptions, one must be aware of the limitations of stress predictions derived from that model.All of the models currently used to calculate wall stresses were reviewed and the following major conclusions were reached: (1) For most applications, detailed knowledge of the stress distribution across the wall is not essential and cannot be verified by current means.The midwall or stress averaged across the wall is adequate.Hence, the Falsetti et al. (1970) thin-walled or the MJrksy (1969, 1979) thickwalled ellipsoidal formulas derived from a generalized Laplace's law are probably the best compromise in terms of ease of computation, and incorporation of realistic albeit greatly oversimplified geometry.Use of thin-or thick-walled spherical formulas underestimate circumferential stresses by about 20-40% and overestimate longitudinal stresses by about 10-20%, respectively.(2) The wide qualitative and quantitative differences predicted by the various analytical thick-walled formulas make it difficult to judge which gives the most realistic representation of the actual stress distribution across the wall and are, thus, of little practical utility.(3) The finite-element method offers an extremely powerful method for analyzing regional variations in stress.This method can account for variations in material properties, complex geometry, anisotropy, and variations in fiber angle from region to region.However, until faster and better methods of accurate three-dimensional reconstruction of the heart are available and until more data on the multiaxial constitutive properties of myocardium are obtained, this method cannot be utilised to its full capabilities.In addition, the effort and expense involved in using the finiteelement method are considerable and will limit its widespread application.(4) Until accurate and reliable methods to measure wall stresses are developed and the predictions of the models are validated, our quantitative knowledge of ventricular wall stress will be incomplete.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.49.4.829

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 374

Metadata

Authors
Yin, F. C.
Venue
Circulation Research
Published
1981-10
Volume
49
Issue
4
Pages
829-842
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W1994079883
Cited by
374
References
0
FWCI
7.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ventricular wall stress. https://app.cochat.ai/papers/10.1161/01.res.49.4.829
The paper
Yin, F. C. (1981). Ventricular wall stress. Circulation Research. https://doi.org/10.1161/01.res.49.4.829

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.