The DOI matches its Crossref record.
Influences of anisotropic tissue structure on reentrant circuits in the epicardial border zone of subacute canine infarcts.
Abstract
Excitation in the epicardial border zone of 3-5-day-old canine infarcts was mapped with an array of 192 bipolar electrodes during sustained ventricular tachycardia. Reentrant circuits were found in which activation occurred around long lines of apparent conduction block based on the criterion that excitation on opposite sides of the lines occurred with marked disparity in time. When the lines of apparent block were functional (i.e., occurred only during tachycardia and not during sinus rhythm or ventricular pacing) they were oriented parallel to the long axis of epicardial muscle fiber bundles. Isochrones distal to the lines were oriented parallel to them because widely separate sites within these isochrones were activated nearly simultaneously. This suggested that excitation not only occurred around the lines of block but also slowly across them. This slow activation occurred transverse to the long axis of the myocardial fibers and therefore might result because of the anisotropic tissue properties. To test this hypothesis, the epicardial border zone was stimulated during sinus rhythm through electrodes around its margin and at the center of the recording array. Activation transverse to the myocardial fibers in regions where lines of block occurred during tachycardia was slow, whereas it was rapid parallel to fibers' orientation. During tachycardia electrograms along the lines of apparent block had long durations and were fractionated, a characteristic that can also result from activation transverse to the myocardial fiber long axis. Therefore, we propose that the parallel orientation of the muscle bundles in the epicardial border zone is an important cause of ventricular tachycardia because activation transverse to myocardial fibers is sufficiently slow to permit the occurrence of reentry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Basic Mechanisms of Cardiac Impulse Propagation and Associated Arrhythmias
KLÉBER, A. G., & RUDY, Y. (2004) · Physiological Reviews · doi:10.1152/physrev.00025.2003 · Cited by 1,083
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Frazier, D. W., Wolf, P. D., Wharton, J. M., Tang, A. S., Smith, W. M., & Ideker, R. E. (1989) · Journal of Clinical Investigation · doi:10.1172/jci113945 · Cited by 386
Hagendorff, A., Schumacher, B., Kirchhoff, S., Lüderitz, B., & Willecke, K. (1999) · Circulation · doi:10.1161/01.cir.99.11.1508 · Cited by 309
Rohr, S., Kucera, J. P., & Kléber, A. G. (1998) · Circulation Research · doi:10.1161/01.res.83.8.781 · Cited by 271
Metadata
- Authors
- Dillon, S. M., Allessie, M. A., Ursell, P. C., & Wit, A. L.
- Venue
- Circulation Research
- Published
- 1988-07
- Volume
- 63
- Issue
- 1
- Pages
- 182-206
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1992189118
- Cited by
- 518
- References
- 0
- FWCI
- 20.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influences of anisotropic tissue structure on reentrant circuits in the epicardial border zone of subacute canine infarcts. https://app.cochat.ai/papers/10.1161/01.res.63.1.182
- The paper
- Dillon, S. M., Allessie, M. A., Ursell, P. C., & Wit, A. L. (1988). Influences of anisotropic tissue structure on reentrant circuits in the epicardial border zone of subacute canine infarcts. Circulation Research. https://doi.org/10.1161/01.res.63.1.182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.