The DOI matches its Crossref record.
Coronary arteriolar myogenic response is independent of endothelium.
Abstract
The purpose of this study was to investigate if myogenic responses of isolated coronary arterioles were dependent on an intact, functional endothelium. Arterioles were located in situ by intracoronary perfusion with india ink-gelatin solution and then dissected and cannulated at both ends with glass micropipettes. Intraluminal pressure was initially set at 60 cm H2O; then the pressure was altered in steps of 20 cm H2O over a range of 20-140 cm H2O. Arterioles developed spontaneous tone and exhibited a significant myogenic response in physiological saline solution (36 degrees -37 degrees C). Arteriolar dilation and constriction were observed at lower (20-60 cm H2O) and higher (60-140 cm H2O) pressures, respectively. The presence of a functional and automatically intact endothelium was confirmed by relaxation to the endothelium-dependent vasodilator bradykinin and by transmission electron microscopy, respectively. After mechanical denudation of the endothelium with a specially designed abrasive micropipette, spontaneous tone and myogenic responses were preserved. Denudation of the endothelium was verified functionally (no response to bradykinin) and with transmission electron microscopy. Moreover, the mechanical denudation technique did not deleteriously affect smooth muscle because vasoconstrictor and vasodilator responses to nonendothelial-dependent drugs were the same before and after denudation. In summary, the present study demonstrates that pressure-dependent responses occur in isolated coronary arterioles and that this response is not dependent on the endothelium. Therefore, pressure-induced changes in coronary arteriolar tone are a true myogenic response in that they originate from smooth muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coronary Microvascular Dysfunction
Camici, P. G., & Crea, F. (2007) · New England Journal of Medicine · doi:10.1056/nejmra061889 · Cited by 1,605
Celermajer, D. S., Sorensen, K. E., Spiegelhalter, D. J., Georgakopoulos, D., Robinson, J., & Deanfield, J. E. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90305-0 · Cited by 1,335
Coronary Microvascular Dysfunction
Crea, F., Lanza, G. A., & Camici, P. G. (2014) · Springer eBooks · doi:10.1007/978-88-470-5367-0 · Cited by 1,287
Retinal Vascular Caliber: Systemic, Environmental, and Genetic Associations
Sun, C., Wang, J. J., Mackey, D. A., & Wong, T. Y. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.10.003 · Cited by 413
Cytochrome P450 and Vascular Homeostasis
Fleming, I. (2001) · Circulation Research · doi:10.1161/hh2101.099268 · Cited by 383
Metadata
- Authors
- Kuo, L., Chilian, W. M., & Davis, M. J.
- Venue
- Circulation Research
- Published
- 1990-03
- Volume
- 66
- Issue
- 3
- Pages
- 860-866
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2076604707
- Cited by
- 237
- References
- 0
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary arteriolar myogenic response is independent of endothelium. https://app.cochat.ai/papers/10.1161/01.res.66.3.860
- The paper
- Kuo, L., Chilian, W. M., & Davis, M. J. (1990). Coronary arteriolar myogenic response is independent of endothelium. Circulation Research. https://doi.org/10.1161/01.res.66.3.860
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.