CoChat

Directional differences in excitability and margin of safety for propagation in sheep ventricular epicardial muscle.

Open access
Delgado, C, Steinhaus, B, Delmar, M, Chialvo, D R, Jalife, J · 1990 · Circulation Research
Cited by 100

The DOI matches its Crossref record.

Abstract

Computer simulations and isolated tissue experiments were used to characterize the relation between excitability and margin of safety for propagation in anisotropic ventricular myocardium. Longitudinal, uniform transverse, and nonuniform transverse tissue directions were modeled in a one-dimensional Beeler-Reuter based cable. Stimulation threshold was smallest in the nonuniform transverse direction. The safety factor for propagation was determined in the model as the total axial charge that was available for depolarizing downstream tissue divided by the threshold charge that was just sufficient for continued propagation and was largest in the longitudinal direction. The strength-interval plot for the junction between simulated longitudinal and nonuniform transverse directions identified a range of stimulus strengths and intervals that resulted in nonuniform transverse but not longitudinal propagation. When high values of transverse resistance were used, higher stimulus strengths during premature stimulation resulted in longitudinal but not nonuniform transverse propagation. The experimental strength interval plots from 17 L-shaped preparations of isolated sheep epicardial muscles had similar characteristics. In nine additional L-shaped tissue experiments, changing extracellular K+ concentrations from 4 to 20 mM resulted in progressive membrane depolarization and conduction impairment in both directions. However, in eight of nine experiments, complete block occurred first in the transverse direction. In one experiment, block was simultaneous in both directions. We conclude that, under normal conditions, threshold requirements for active propagation are lower for transverse than for longitudinal propagation. In addition, when active membrane properties are impaired, the safety factor for propagation is larger in the direction along the longitudinal axis of the cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.res.67.1.97

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 100

Metadata

Authors
Delgado, C., Steinhaus, B., Delmar, M., Chialvo, D. R., & Jalife, J.
Venue
Circulation Research
Published
1990-07
Volume
67
Issue
1
Pages
97-110
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2042486482
Cited by
100
References
0
FWCI
4.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Directional differences in excitability and margin of safety for propagation in sheep ventricular epicardial muscle. https://app.cochat.ai/papers/10.1161/01.res.67.1.97
The paper
Delgado, C., Steinhaus, B., Delmar, M., Chialvo, D. R., & Jalife, J. (1990). Directional differences in excitability and margin of safety for propagation in sheep ventricular epicardial muscle. Circulation Research. https://doi.org/10.1161/01.res.67.1.97

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.